Warmup 4iE Operating Manual - page 12
Fil Pilote
This is a feature specifically for France. You must also connect Fil Pilote to terminal 1
Master/Relay
This allows one thermostat to control another
1.
Choose which thermostat is Master and which is Relay
2.
Use low voltage cable to connect terminal 6 of both thermostats
3.
Use low voltage cable to connect terminal 7 of both thermostats (in addition
to floor sensor cables on the Master thermostat)
4.
Set Relay thermostat to Relay mode first, then set the Master thermostat to
Master mode
5.
Program the Master thermostat. The Relay thermostat will no longer use its
sensors, it will follow the Master thermostat
Gradual Start
Set the maximum temperature and time required to reach that temperature
Probes
Set the specification of the probes. You can also choose to hide the error message if you do not want to
connect a probe
Probe application
Choose if the floor probe is being used as a Floor or Amb (ambient) sensor
Offset
Set the offset of the sensors to improve accuracy
Reset
This will restore all the factory default settings. You can also hold the button on the rear of the front
module for 10 seconds to perform a system reset
Advanced settings
These options can affect the performance of your thermostat and should only be modified by an
experienced professional or under the instruction of Warmup Technical Support
Heater settings
Heater limits
Set the temperature limits for your floor type.
User Defined lets you set custom
limits
Regulator
Regulator mode controls the heating in 10 minute cycles. The number you enter is
the number of minutes in every 10 minute cycle that the heating will be on. This
mode will not use the floor or air sensors for measurement
12