Wasco Solar Smart EVMS Installation & User Manual - page 13
INSTALLATION & USER MANUAL
13
Solar Smart Operator
Installation and User Manual
Revision 8.12.2015
14
SETTING TEMPERATURE CONTROL (TC)
•
Automated temperature control (TC) can be set for all operators within a zone; and each
zone may have a unique TC value.
•
When set and the remote is set to AUTO, the temperature control will open the operator(s)
within a zone when the temperature setting is reached.
•
It will close the operator(s) when the temperature drops greater than 5 degrees (F) or 2
degrees (C) below the set level.
•
This automatic function is based on the temperature at the remotes location and must be
maintained for approximately 5 minutes.
1. Press any key to wake up the remote, if the LCD display has powered off.
2. Press MODE .
3. Press ZONE as necessary to choose the appropriate zone (1 thru 9).
4. Press ENTER to save your selection.
5. MAX-OPEN will be displayed and flashing.
6. Press
▲ ▼ until TC is displayed and flashing.
7. Press ENTER .
8. Press
▲ ▼ to set the desired temperature, or NULL to turn function off, for this zone.
9. Press ENTER to save your selection.
•
The temperature in which the operator will run has now been set. Next, a MAX-OPEN
limit is set specifically for when the TC function opens the operator. This MAX-OPEN
cannot exceed the limit set for basic operation.
10. Press
▲ ▼ to set the percentage, in increments of 10%, of the temperature controlled
MAX-OPEN. Operator(s) will not open past MAX-OPEN set above.
Press ENTER to save your setting.
11. P1 is now displayed.
12. Press MODE to return to the home screen - OR - to continue on to check the status of the
batteries and charge current.
•
After any change to the TC settings, the TC function will be enabled and AUTO will be
displayed.
Enable / Disable the TC Function
1. Press and hold the AUTO button for 2 seconds until the screen changes. The screen
will read either AUTO/TC, AUTO/P1, or be blank which disables both automatic
functions. Each time you press and hold the AUTO button for 2 seconds it will scroll
the screen to the next option. When the correct Auto Function is displayed, you are
done.