REMOTE DISPLAY
TROUBLESHOOTING TIPS
1. If in AUTO mode and operator(s) is not working as expected, make sure none of the secondary remotes are set to AUTO mode
and that temperature control (TC) for all zones on secondary remotes are set to NULL.
2. MAX-OPEN can be set to different values on both the main and secondary remotes. The operator will open to the MAX-OPEN
setting of the remote used to open it. If the operator is not opening the proper amount be sure to check that MAX-OPEN is set
properly on the remote used.
3. Temperature control (TC) may also have to be set to have a lower MAX-OPEN value than the otherwise set MAX-OPEN.
4. Temperature change must be maintained for 10 minutes before the temperature control (TC) function will operate.
For more Trouble Shooting Tips, please visit www.SolarSmartOpener.com
ADVANCED SERVICE OPERATIONS
RESET OF REMOTE TO FACTORY SETTINGS
1. Press any key to wake up the remote, if the display has powered off.
2. Press and hold MODE , release when PAIR
SET
is displayed.
3. Press MODE again to display RE-ZONE.
4. Press MODE to display M in the upper-right corner as flashing.
5. Press ENTER
FAIL is displayed as flashing.
6. Press and hold MODE , release when rF TEST is displayed.
7. Press MODE repeatedly until rET FAC is displayed.
8. Press ENTER , all the screen display segments will be visible while the remote runs a self-test which lasts for a few seconds.
After which,
SET
will be displayed.
The remote has now been reset to factory settings; it is no longer paired to any operators.