Wascomat EX-30 S and EX-50 S Operating & Maintenance Manual - Installation
18
Installation
15
Fig.
15
4724 B
Electrical installation
Electrical installation must be carried out
by an authorized personnel!
Mount a multi-pole switch prior to the machine to
facilitate installation and service operations.
The connecting cable should hang in a gentle
curve.
Fuse size can be found on next page.
Single-phase connection:
Connect the earth and other two wires as shown
in example "1AC" in the figure.
Three-phase connection:
Connect the earth, neutral and phase wires as
shown in example "3AC" in the figure.
When the installation is completed, check:
•
that the drum is empty,
•
that the machine operates by turning on the
mains switch, starting the machine and using
RAPID ADVANCE to reach the spin cycle
(see operations manual).
16
4726
Fig.
16
T1
T2
T3
L1
N
N
L2
L3
T1
T2
T3
L1
N
N
L2
L3
1AC
3AC