Wasp WWS800 Reference Manual

Other manuals for WWS800: User Manual, User Manual, User Manual, User Manual
Manual is about: Bluetooth Wireless Scanners

Summary of WWS800

  • Page 1

    Table of contents restore default settings ............................................1 exit setup without changes......................................1 set connection ...........................................................1 rf auto shutdown duration....................................1 memory...

  • Page 2

    1 update restore default settings exit setup without changes set connection * programming instructions : (1) read the label. (2) read the serial number barcode on the bottom of the desired wws800 base station within 5 seconds to complete this setting. Rf auto shutdown duration * programming instruct...

  • Page 3

    3 update list setting page1 page 6 page 2 page 7 page 3 page 8 page 4 page 9 page 5 page 10 buzzer settings buzzer disable • buzzer frequency 8 khz 2 khz 1 khz 4 enter setup reading redundancy setting 2 times 3 times 4 times scan mode setting auto off mode auto power off mode alternate mode momentar...

  • Page 4

    5 update scanner time-out duration * programming instructions : (1) read the label. (2) program the desired time-out duration by reading decimal digits on page 49. (3) read the “validate” label (also on page 49) to complete this setting. Negative barcode setting enable disable > delay between reread...

  • Page 5

    7 update • keyboard alphabets layout azerty qwertz • keyboard digits layout lower row upper row • keyboard capital lock type shift lock capital lock • capital lock setting capital lock on auto detection 8 enter setup • alphabet transmission ignore case • digits transmission numeric key • alt composi...

  • Page 6

    9 update rs-232 parameters • activate rs232 interface • baud rate 115200 38400 19200 4800 2400 1200 300 • parity even odd • data bit 7 10 enter setup • flow control scanner ready data ready inv. Data ready • inter-character delay * programming instructions : (1) read the label. (2) program the desir...

  • Page 7

    11 update bluetooth serial port parameters • activate bluetooth serial port interface • device name broadcasting no • authentication yes no > • pin code * programming instructions : (1) read the label. (2) program the desired character string by reading hexadecimal digits on page 50. One character c...

  • Page 8

    13 update code id setting code 39 * italy pharmacode * french pharmacode * industrial 25 * interleave 25 * matrix 25 * codabar * upca * upce * ean8 * ean13 * code 93 * code 128 * msi * plessey * telepen * programming instructions : (1) read the label. (2) program the desired character string by read...

  • Page 9

    15 update • matrix 25 length code enable disable > • codabar length code enable disable > • upca length code enable disable > • upce length code enable disable > • ean8 length code enable disable > • ean13 length code enable disable > 16 enter setup • code 93 length code enable • code 128 length cod...

  • Page 10

    17 update select readable codes • code 39 disable • italy pharmacode enable disable > • french pharmacode enable disable > • industrial 25 disable • interleave 25 disable 18 enter setup • matrix 25 enable • codabar disable • code 93 disable • code 128 disable • ean128 enable • msi enable.

  • Page 11

    19 update • plessey enable disable > • telepen enable disable > • upca disable no addon enable addon2 enable addon5 20 enter setup • upce disable no addon enable addon2 enable addon5 • ean8 disable no addon enable addon2 enable addon5.

  • Page 12

    21 update • ean13 disable no addon enable addon2 enable addon5 rss14 enable disable > • rss limited enable disable > • rss expanded enable disable > 22 enter setup code39 parameters • standard / full ascii code39 full ascii • start / stop transmission enable • checksum verification enable • checksum...

  • Page 13

    23 update french pharmacode parameters • checksum transmission disable industrial 25 parameters • start / stop selection interleave 25 matrix 25 • checksum verification enable disable > • checksum transmission disable 24 enter setup • max / min code length qualification select max / min length quali...

  • Page 14

    25 update • checksum verification enable disable > • checksum transmission disable • max / min code length qualification select max / min length qualification max length * min length * programming instructions : (1) read the label. (2) program the desired length by reading decimal digits on page 49....

  • Page 15

    27 update • max / min code length qualification select max / min length qualification max length * min length * • fixed code length qualification select fixed length qualification fixed length 1 * fixed length 2 * programming instructions : (1) read the label. (2) program the desired length by readi...

  • Page 16

    29 update msi parameters • checksum verification double modulo 10 modulo 11 & 10 • checksum transmission transmitted last 2 digits not transmitted • max / min code length qualification select max / min length qualification max length * min length * programming instructions : (1) read the label. (2) ...

  • Page 17

    31 update ean8 parameters • convert to ean13 enable disable > • checksum transmission disable upca parameters • convert to ean13 disable • system number transmission disable • checksum transmission disable 32 enter setup upce parameters • system number selection system number 0 and 1 • convert to up...

  • Page 18

    33 update ean13 parameters • isbn conversion enable disable > • issn conversion enable disable > • checksum transmission disable 34 enter setup rss code id selection ]c1 rss14 parameters • code id transmission disable • application id transmission disable • checksum transmission disable.

  • Page 19

    35 update rss limited parameters • code id transmission disable • application id transmission disable • checksum transmission disable rss limited parameters • code id transmission disable 36 enter setup activate editing formats • format 1 enable • format 2 enable • format 3 enable • exclusive data e...

  • Page 20

    37 update editing format parameters • format selection format 1 format 2 format 3 • restore default format 38 end of format programming • applicable data length maximum length * minimum length * programming instructions : (1) read the label. (2) program the desired length by reading decimal digits o...

  • Page 21

    39 update • total number of fields 1 4 2 5 3 6 40 end of format programming • applicable code type all clear code 39 italy pharmacode french pharmacode industrial 25 interleave 25 matrix 25 codebar code 93 code 128 ean128 / rss upce no addon upce addon2 upce addon5 ean8 no addon ean8 addon2 ean8 add...

  • Page 22

    41 update ean13 no addon ean13 addon2 ean13 addon5 upca no addon upca addon2 upca addon5 msi plessey 42 end of format programming • field1 setting divide field by field terminating string field terminating string * programming instructions : (1) read the label. (2) program the desired character stri...

  • Page 23

    43 update • field2 setting divide field by field terminating string field terminating string * programming instructions : (1) read the label. (2) program the desired character string by reading hexadecimal digits on page 50. One character consists of 2 hexadecimal digits. (3) read the “validate” lab...

  • Page 24

    45 update • field4 setting divide field by field terminating string field terminating string * programming instructions : (1) read the label. (2) program the desired character string by reading hexadecimal digits on page 50. One character consists of 2 hexadecimal digits. (3) read the “validate” lab...

  • Page 25

    47 update • additional fields setting additional field 1 * additional field 4 * additional field 2 * additional field 5 * additional field 3 * programming instructions : (1) read the label. (2) program the desired character string by reading hexadecimal digits on page 50. One character consists of 2...

  • Page 26

    49 update decimal digits 0 5 1 6 2 7 3 8 4 9 • validate 50 enter setup hexadecimal digits 0 8 1 9 2 a 3 b 4 c 5 d 6 e 7 f • validate.

  • Page 27

    51 update rs-232 character table 0 1 2 3 4 5 6 7 0 dle sp 0 @ p ` p 1 soh dc1 ! 1 a q a q 2 stx dc2 " 2 b r b r 3 etx dc3 # 3 c s c s 4 eot dc4 $ 4 d t d t 5 enq nak % 5 e u e u 6 ack syn & 6 f v f v 7 bel etb ' 7 g w g w 8 bs can ( 8 h x h x 9 ht em ) 9 i y i y a lf sub * : j z j z b vt esc + ; k [...