- DL manuals
- Wasp
- Barcode Reader
- WWS800
- Reference Manual
Wasp WWS800 Reference Manual - page 12
21
Update
• EAN13
< Enable No Addon >
Disable No Addon
Enable Addon2
< Disable Addon2 >
Enable Addon5
< Disable Addon5 >
RSS14
Enable
<
Disable
>
• RSS Limited
Enable
<
Disable
>
• RSS Expanded
Enable
<
Disable
>
22
Enter Setup
Code39 Parameters
• Standard / Full ASCII Code39
< Standard >
Full
ASCII
• Start / Stop Transmission
Enable
< Disable >
• Checksum Verification
Enable
< Disable >
• Checksum Transmission
< Enable >
Disable
Italy Pharmacode Parameters
• Checksum Transmission
< Enable >
Disable>
Summary of WWS800
Page 1
Table of contents restore default settings ............................................1 exit setup without changes......................................1 set connection ...........................................................1 rf auto shutdown duration....................................1 memory...
Page 2
1 update restore default settings exit setup without changes set connection * programming instructions : (1) read the label. (2) read the serial number barcode on the bottom of the desired wws800 base station within 5 seconds to complete this setting. Rf auto shutdown duration * programming instruct...
Page 3
3 update list setting page1 page 6 page 2 page 7 page 3 page 8 page 4 page 9 page 5 page 10 buzzer settings buzzer disable • buzzer frequency 8 khz 2 khz 1 khz 4 enter setup reading redundancy setting 2 times 3 times 4 times scan mode setting auto off mode auto power off mode alternate mode momentar...
Page 4
5 update scanner time-out duration * programming instructions : (1) read the label. (2) program the desired time-out duration by reading decimal digits on page 49. (3) read the “validate” label (also on page 49) to complete this setting. Negative barcode setting enable disable > delay between reread...
Page 5
7 update • keyboard alphabets layout azerty qwertz • keyboard digits layout lower row upper row • keyboard capital lock type shift lock capital lock • capital lock setting capital lock on auto detection 8 enter setup • alphabet transmission ignore case • digits transmission numeric key • alt composi...
Page 6
9 update rs-232 parameters • activate rs232 interface • baud rate 115200 38400 19200 4800 2400 1200 300 • parity even odd • data bit 7 10 enter setup • flow control scanner ready data ready inv. Data ready • inter-character delay * programming instructions : (1) read the label. (2) program the desir...
Page 7
11 update bluetooth serial port parameters • activate bluetooth serial port interface • device name broadcasting no • authentication yes no > • pin code * programming instructions : (1) read the label. (2) program the desired character string by reading hexadecimal digits on page 50. One character c...
Page 8
13 update code id setting code 39 * italy pharmacode * french pharmacode * industrial 25 * interleave 25 * matrix 25 * codabar * upca * upce * ean8 * ean13 * code 93 * code 128 * msi * plessey * telepen * programming instructions : (1) read the label. (2) program the desired character string by read...
Page 9
15 update • matrix 25 length code enable disable > • codabar length code enable disable > • upca length code enable disable > • upce length code enable disable > • ean8 length code enable disable > • ean13 length code enable disable > 16 enter setup • code 93 length code enable • code 128 length cod...
Page 10
17 update select readable codes • code 39 disable • italy pharmacode enable disable > • french pharmacode enable disable > • industrial 25 disable • interleave 25 disable 18 enter setup • matrix 25 enable • codabar disable • code 93 disable • code 128 disable • ean128 enable • msi enable.
Page 11
19 update • plessey enable disable > • telepen enable disable > • upca disable no addon enable addon2 enable addon5 20 enter setup • upce disable no addon enable addon2 enable addon5 • ean8 disable no addon enable addon2 enable addon5.
Page 12
21 update • ean13 disable no addon enable addon2 enable addon5 rss14 enable disable > • rss limited enable disable > • rss expanded enable disable > 22 enter setup code39 parameters • standard / full ascii code39 full ascii • start / stop transmission enable • checksum verification enable • checksum...
Page 13
23 update french pharmacode parameters • checksum transmission disable industrial 25 parameters • start / stop selection interleave 25 matrix 25 • checksum verification enable disable > • checksum transmission disable 24 enter setup • max / min code length qualification select max / min length quali...
Page 14
25 update • checksum verification enable disable > • checksum transmission disable • max / min code length qualification select max / min length qualification max length * min length * programming instructions : (1) read the label. (2) program the desired length by reading decimal digits on page 49....
Page 15
27 update • max / min code length qualification select max / min length qualification max length * min length * • fixed code length qualification select fixed length qualification fixed length 1 * fixed length 2 * programming instructions : (1) read the label. (2) program the desired length by readi...
Page 16
29 update msi parameters • checksum verification double modulo 10 modulo 11 & 10 • checksum transmission transmitted last 2 digits not transmitted • max / min code length qualification select max / min length qualification max length * min length * programming instructions : (1) read the label. (2) ...
Page 17
31 update ean8 parameters • convert to ean13 enable disable > • checksum transmission disable upca parameters • convert to ean13 disable • system number transmission disable • checksum transmission disable 32 enter setup upce parameters • system number selection system number 0 and 1 • convert to up...
Page 18
33 update ean13 parameters • isbn conversion enable disable > • issn conversion enable disable > • checksum transmission disable 34 enter setup rss code id selection ]c1 rss14 parameters • code id transmission disable • application id transmission disable • checksum transmission disable.
Page 19
35 update rss limited parameters • code id transmission disable • application id transmission disable • checksum transmission disable rss limited parameters • code id transmission disable 36 enter setup activate editing formats • format 1 enable • format 2 enable • format 3 enable • exclusive data e...
Page 20
37 update editing format parameters • format selection format 1 format 2 format 3 • restore default format 38 end of format programming • applicable data length maximum length * minimum length * programming instructions : (1) read the label. (2) program the desired length by reading decimal digits o...
Page 21
39 update • total number of fields 1 4 2 5 3 6 40 end of format programming • applicable code type all clear code 39 italy pharmacode french pharmacode industrial 25 interleave 25 matrix 25 codebar code 93 code 128 ean128 / rss upce no addon upce addon2 upce addon5 ean8 no addon ean8 addon2 ean8 add...
Page 22
41 update ean13 no addon ean13 addon2 ean13 addon5 upca no addon upca addon2 upca addon5 msi plessey 42 end of format programming • field1 setting divide field by field terminating string field terminating string * programming instructions : (1) read the label. (2) program the desired character stri...
Page 23
43 update • field2 setting divide field by field terminating string field terminating string * programming instructions : (1) read the label. (2) program the desired character string by reading hexadecimal digits on page 50. One character consists of 2 hexadecimal digits. (3) read the “validate” lab...
Page 24
45 update • field4 setting divide field by field terminating string field terminating string * programming instructions : (1) read the label. (2) program the desired character string by reading hexadecimal digits on page 50. One character consists of 2 hexadecimal digits. (3) read the “validate” lab...
Page 25
47 update • additional fields setting additional field 1 * additional field 4 * additional field 2 * additional field 5 * additional field 3 * programming instructions : (1) read the label. (2) program the desired character string by reading hexadecimal digits on page 50. One character consists of 2...
Page 26
49 update decimal digits 0 5 1 6 2 7 3 8 4 9 • validate 50 enter setup hexadecimal digits 0 8 1 9 2 a 3 b 4 c 5 d 6 e 7 f • validate.
Page 27
51 update rs-232 character table 0 1 2 3 4 5 6 7 0 dle sp 0 @ p ` p 1 soh dc1 ! 1 a q a q 2 stx dc2 " 2 b r b r 3 etx dc3 # 3 c s c s 4 eot dc4 $ 4 d t d t 5 enq nak % 5 e u e u 6 ack syn & 6 f v f v 7 bel etb ' 7 g w g w 8 bs can ( 8 h x h x 9 ht em ) 9 i y i y a lf sub * : j z j z b vt esc + ; k [...