Water Right Impression Plus Series Installation Instructions & Owner's Manual

Summary of Impression Plus Series

  • Page 1

    Impression series ® and impression plus series ® water filters for models: • imbf • imbf-man • iman • imaf-mgs • ims • imb • iag • iacg-an • impbf • impbf-man • impaf-mgs • imps • impb • ipag • ipacg-an.

  • Page 2: Table of Contents

    Table of contents preinstallation instructions for dealers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 bypass valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 installation . . . . . . . . . . . . . . . . ....

  • Page 3

    Preinstallation instructions for dealers: 3 the manufacturer has preset the water treatment unit’s sequence of cycles and cycle times . The dealer should read this page and guide the installer regarding hardness, day override, and time of regeneration, before installation. For the installer, the fol...

  • Page 4: Bypass Valve:

    4 the bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control valve repairs or maintenance . The 1” full flow bypass valve incorporates four positions, including a diagnostic position that allows a service technician to have p...

  • Page 5: Installation:

    5 general installation & service warnings the control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments . There is a small amount of “give” to properly connect the piping, but the water softener is not designed to support the weight of the plumbing . Do not use v...

  • Page 6

    6 when installing an air regenerating filter the customer may experience, under certain conditions, small amounts of air (cloudy water) at the taps . This is normal . On rare occasions, this may result in “shots of air” at a particular fixture . By installing a loop or “u” on the outlet side of the ...

  • Page 7

    7 8 . Check valve: all air systems include an internal check valve and screen assembly as part of the air draw system (see diagram at right) . This check valve, screen, and elbow are exclusive to the air system and are not to be confused or interchanged with a brine elbow used on a softener . The gr...

  • Page 8: Programming Procedures:

    8 time of day should only need to be set after extended power outages or when daylight saving time begins or ends . If an extended power outage occurs, the time of day will flash on and off indicating that the time should be reset . Step 1 – press set clock . Step 2 – current time (hour): set the ho...

  • Page 9: Startup Instructions:

    Startup instructions: 9 flushing of system: to flush the system of any debris and air after installation is complete, please perform the following steps: 1 . Rotate bypass handles to the bypass mode (see fig. 2 of page 4) . 2 . Turn on inlet water and check for leaks in the newly installed plumbing ...

  • Page 10

    10 operating displays and instructions: 1 . General operation:when the system is operating, one of three displays may be shown . Pressing next will alternate between the displays . One of the displays is always the current time of day . The second display shows the current treated water flow rate th...

  • Page 11

    11 5 . Error message:if the word “error” and a number are alternately flashing on the display record the number and contact the dealer for help . This indicates that the control valve was not able to function properly . 6 . Chlorine tank and maintenance: in severe cases where iron or sulfate bacteri...

  • Page 12: For Acid Neutralizers:

    12 1 . Check the media height by shining a flashlight through the tank to see the height of the mineral . If the level is not seen, the top fill plug will have to be removed (if available) to measure the height . Proceed to step 2 . 2 . To remove top fill plug, turn off the source of the water and o...

  • Page 13: Troubleshooting Guide:

    13 problem cause correction 1. No display on pc board a . No power at electric outlet a . Repair outlet or use working outlet b . Control valve power adapter not plugged into outlet or power cord end not connected to pc board connection b . Plug power adapter into outlet or connect power cord end to...

  • Page 14

    7. Control valve does not regenerate automatically but does when the correct button(s) is depressed and held. For timeclock valves the buttons are s & t. For all other valves the button is regen. A . Bypass valve in bypass position a . Turn bypass handles to place bypass in service position b . Mete...

  • Page 15

    15 12. Control valve fails to draw in regenerant a . Injector is plugged a . Remove injector and clean or replace b . Faulty regenerant piston b . Replace regenerant piston c . Regenerant line connection leak c . Inspect regenerant line for air leak d . Drain line restriction or debris cause excess ...

  • Page 16

    16 16. E3, err – 1003, err – 103 = control valve motor ran too long and was unable to find the next cycle position a . Motor failure during a regeneration a . Check motor connections then press next and regen buttons for 3 seconds to resynchronize software with piston position or disconnect power su...

  • Page 17: Replacement Parts:

    17 replacement parts: 2 7 1 3 5 4 6 front cover and drive assembly item no. Part no. Description qty. 1 cv3540-a black impression ® cover 1 cv3540-w-a gray impression ® cover 1 cv3540p-a black impression plus ® cover 1 cv3540p-w-a gray impression plus ® cover 1 2 cv3107-1 motor 1 3 cv3106-1 drive br...

  • Page 18: Replacement Parts:

    6 8 10 11 7 9 7 12 4 2 3 5 1 13 14 note: for impression plus ® models only. Not available on 1¼ " valve. Replacement parts: for impression plus ® models only piston assembly item no. Part no. Description qty. 1 cv3005 1” spacer stack assembly 1 cv3430 1 .25” spacer stack assembly 1 2 cv3004 drive ca...

  • Page 19: Replacement Parts:

    19 replacement parts: bypass valve item no. Part no. Description qty. 1 cv3151 nut, 1” quick connect 2 2 cv3150 split ring 2 3 cv3105 o-ring 215 2 4 cv3145 bypass rotor, 1” 2 5 cv3146 bypass cap 2 6 cv3147 bypass handle 2 7 cv3148 bypass rotor seal retainer 2 8 cv3152 o-ring 135 2 9 cv3155 o-ring 11...

  • Page 20: Replacement Parts:

    Injector assemblies item no. Part no. Description qty. 1 cv3176 injector cap 1 2 cv3152 o-ring 135 1 3 cv3177-01 injector screen 1 4 cv3010-1z injector assembly plug 1 5 cv3010-1a a injector assembly, black 1 cv3010-1b b injector assembly, brown cv3010-1c c injector assembly, violet cv3010-1d d inje...

  • Page 21: Replacement Parts:

    21 replacement parts: drain line assembly 3/4” item no. Part no. Description qty. 1 ch4615 elbow locking clip 1 2 cpkp10ts8-bulk optional insert, 5/8” tube 1 3 cv3192 optional nut, 3/4” drain elbow 1 4 cv3158-01 drain elbow, 3/4” npt with o-ring 1 5 cv3163 o-ring 019 1 6 cv3159-01 dlfc retainer asse...

  • Page 22: Replacement Parts:

    Replacement parts: although no tools are necessary to assemble or disassemble the valve, the service wrench, (shown in various positions on the valve) is available to aid in assembly or disassembly . Service wrench - cv3193-02 22 chlorine tank assembly item no. Part no. Description qty. 1 ch4600-50 ...

  • Page 23

    23 1” pvc male npt elbow item no. Part no. Description qty. Cv3007 1” pvc male npt elbow assembly 2 1 cv3151 nut, 1” quick connect 2 2 cv3150 split ring 2 3 cv3105 o-ring 215 2 4 cv3149 fitting 2 3/4” & 1” pvc solvent elbow item no. Part no. Description qty. Cv3007-01 3/4” & 1” pvc solvent elbow ass...

  • Page 24

    1-1/4” & 1-1/2” pvc solvent item no. Part no. Description qty. Cv3007-07 1-1/4” & 1-1/2” pvc solvent assembly 2 1 cv3151 nut, 1” quick connect 2 2 cv3150 split ring 2 3 cv3105 o-ring 215 2 4 cv3352 fitting 2 1-1/4” & 1-1/2” brass sweat item no. Part no. Description qty. Cv3007-09 1-1/4 & 1-1/2” bras...

  • Page 25

    25 acid neutralizers backwashing filters iron filters mineral type calcite or mix calcite or mix calcite or mix calcite or mix calcite or mix calcite or mix amount (cu ft) 1 .0 1 .5 2 .5 1 .0 1 .5 2 .5 gravel amount/size (no . 1) 14 lb 1/4 x 1/8 14 lb 1/4 x 1/8 21 lb 1/4 x 1/8 14 lb 1/4 x 1/8 14 lb ...

  • Page 26

    26 width height sulfur and iron air filters mineral type catalytic carbon catalytic carbon catalytic carbon birm birm birm amount (cu ft) 1 .0 1 .5 2 .0 1 .0 1 .5 2 .0 gravel amount/size (no . 1) 14 lb 1/4 x 1/8 21 lb 1/4 x 1/8 21 lb 1/4 x 1/8 14 lb 1/4 x 1/8 21 lb 1/4 x 1/8 21 lb 1/4 x 1/8 gravel a...

  • Page 27

    27 water conditioner limited warranty congratulations. You have purchased one of the finest water treatment systems available. In the unlikely event of a problem due to defects in material and workmanship, we proudly warrant our water conditioners to the original owner, when installed in accordance ...

  • Page 28: Quick Reference Guide:

    1900 prospect court • appleton, wi 54914 phone: 920-739-9401 • fax: 920-739-9406 manual regeneration note: if you need to initiate a manual regeneration, either immediately, or the same night at the preprogrammed time for regeneration (typically 12:00 am), complete the following steps . For immediat...