OPERATING DISPLAYS AND INSTRUCTIONS:
1 .
GENERAL OPERATION:When the system is operating, one of three
displays may be shown . Pressing
next
will alternate between the displays .
One of the displays is always the current time of day . The second display
shows the current treated water flow rate through the system in Gallons Per
Minute . The third display is capacity remaining . Capacity remaining is the
gallons that will be treated before the system goes through a regeneration
cycle . The user can scroll between the displays as desired .
If the system has called for a regeneration that will occur at the preset time
of regeneration, the words “REGEN TODAY” will appear on the display .
If a water meter is installed, the word “Softening” or “Filtering” flashes on the
display when water is being treated (i .e . water is flowing through the system) .
2 .
REGENERATION MODE:Typically a system is set to regenerate
at a time of no water use . If there is a demand for water when the system
is regenerating, untreated water will be delivered . When the system begins
to regenerate, the display will change to include information about the
step of the regeneration process and the time remaining for that step to be
completed . The system runs through the steps automatically and will reset
itself to provide treated water when the regeneration has been completed .
3 .
MANUAL REGENERATION:Sometimes there is a need to regenerate
before the control valve calls for it . This may be needed if a period of
heavy water use is anticipated or when the system has been operated
without salt .
• To initiate a manual regeneration at the next preset regeneration
time, press and release
regen
. The words “REGEN TODAY” will
flash on the display to indicate that the system will regenerate at
the next regeneration time (set in Programming, steps 4 and 5) . If
you pressed the
regen
button in error, pressing the button again
will cancel the command.
• To initiate a manual regeneration immediately, press and hold the
regen
button for three seconds . The system will begin to regenerate
immediately .
This command cannot be cancelled.
Once a manual regeneration is initiated, the unit will go into the
BACKWASH position and subsequent positions thereafter (see Start-Up
Instructions for regeneration sequence), the water filter will deliver water,
but it will be untreated .
4 .
POWER LOSS AND BATTERY REPLACEMENT:The AC transformer
comes with a 15 foot power cord and is designed for use with the control
valve; the transformer should only be used in a dry location .
In the event of a power outage that is less than 24 hours, the control valve
will remember all settings and time of day . After 24 hours, the only item that
needs to be reset is the time of day and will be indicated by the time of day
flashing . All other settings are permanently stored in the nonvolatile memory .
If a power loss occurs that is less than 24 hours and the time of day
flashes, this indicates that the battery is depleted . The time of day should
be reset and the non-rechargeable battery should be replaced . The battery
is a 3 Volt Lithium Coin Cell type 2032 and is readily available at most
stores . To access battery location, remove front cover (see diagram on
page 14 for battery location).
GENERAL OPERATION DISPLAYS
REGENERATION MODE
MANUAL REGENERATION
BATTERY REPLACEMENT