Watkins CalderaSpas Utopia Series Owner's Manual - Operating Instructions
26
OPERATING INSTRUCTIONS
JeTs BuTTOn
There are two buttons which affect the jet pumps (three buttons on the Cantabria
™
). Pressing any JETS button once will illuminate the jets symbol
on the control panel display. The symbol will remain lit until the jet pump is turned off (see chart below), or after one hour of continuous operation
when the pumps are automatically shut off by the control system.
Geneva
™
, niagara
®
, Tahitian
®
, and elation
®
models:
Cantabria model:
JETS 1 button
JETS 2 button
JETS 1 button
JETS 2 button
JETS 3 button
1st press:
2nd press:
3rd press:
Jet pump 1 on.
Jet pump 1 off.
N/A
Jet pump 2 on low speed.
Jet pump 2 on high speed.
Jet pump 2 off.
1st press:
2nd press:
3rd press:
4th press:
5th press:
Jet pump 1 on low speed.
Jet pump 1 on high speed.
Jet pump 1 off.
N/A
N/A
Jet pump 2 on low speed.
Jet pump 2 on high speed.
Jet pump 2 off.
Jet pump 3 on high speed.
Jet pump 3 off.
Manual Clean CYCle
The “CLEAN” button has been provided as a convenient timer for water maintenance. When the “CLEAN” button is pressed, Jet pump 1 will activate. The jet pump
symbol will flash on and off until the cleaning cycle is complete. The total cleaning cycle time is ten minutes. On the Cantabria, press the SET and AIR & CLEAN buttons
tostartthecleancycle.Forallspas,ifthecleancycledoesnotengage,makesuretheSPALOCKisdeactivated.SPALOCKdisablesthecontrolsonboththemainand
auxiliary control panels.
aIr JeTs BuTTOn
(available on Cantabria, Geneva, niagara and Tahitian spas)
The “AIR” button activates the air blower. When the “AIR” button is pressed, the air symbol
will illuminate on the control panel display. The
symbol will remain lit until the button is pressed to turn off the air blower, or after fifteen minutes when the blower is automatically shut off by the
control system. While the air blower is on, air-only jets are operating throughout the spa. To stop the air blower when active, press the “AIR” button.
On the Cantabria, press the AIR & CLEAN button to activate the blower. To stop the blower, press the AIR & CLEAN button again.
lIGHT BuTTOn
The “LIGHT” button activates the SpaGlo
®
multi-zone lighting system and controls its intensity. Pressing the “LIGHT” button operates the light as
follows:
1st press of the “LIGHT” button: all lights on.
•
2nd press: bartop lights off.
•
3rd press: waterfall light off.
•
4th press: main light, Euphoria
•
®
Jet,andGrabBarlightsonmediumintensity;externalsconcelightsonfullintensity.
5thpress:mainlight,EuphoriaJet,andGrabBarlightsonlowintensity;externalsconcelightsonfullintensity.
•
6thpress:mainlight,EuphoriaJet,andGrabBarlightsoff;externalsconcelightsonfullintensity.
•
7th press: all lights off.
•
If the external sconce lights are left on, they will automatically be turned off by the control system after six hours of continuous operation. The light symbol on the
control panel will also turn off when the lights are deactivated.
To start the SpaGlo color wheel, press the “SET” + “LIGHT” buttons simultaneously while the light is on. The color wheel begins at blue and cycles through the six
color options. The light symbol will flash on and off. To stop the color wheel at your color choice, press the “SET” + “LIGHT” buttons again. The light symbol will display
constant. If you start the color wheel again, it will begin at blue and cycle through the other colors.
If the light is left on, it will automatically be turned off by the control system after six hours of continuous operation. The light symbol on the control panel will also turn off.
Ifthelightwillnotturnon,makesureSPALOCKisdeactivated.SPALOCKdisablesthecontrolsonboththemainandauxiliarycontrolpanel.(SeetheSPALOCK
sectionformoreinformationontheSPALOCKfeature.)
auTOMaTIC lIGHT FeaTure
The Automatic Light Feature allows you to set the SpaGlo lighting system (external sconce lights only) to activate at the same time every day. Wait
forthetimeofdayyouwouldliketheautomaticfeaturetostart,thenpressandhold“TEMP▲”and“LIGHT”buttonsimultaneouslyfor3seconds,
thelightthenremainsactiveforthenext6hours.Thelightingwillturnoneverydayatthesametimeuntilyoupressandholdthe“TEMP▲”and
“LIGHT” button simultaneously for 3 seconds a second time to deactivate the automatic light feature.
suMMer MODe
Your Caldera
®
spa is equipped with a Summer Mode timer. The Summer Mode timer can be activated during extremely hot summer months if it becomes difficult to
maintain water temperatures low enough for comfort. When you turn on the Summer Mode timer, the heater will immediately shut down while the circulation pump (which
can add heat to the water through normal operation) will remain on for approximately 5 minutes for heater cool-down. Both the heater and circulation pump will remain
off for the next 8 hours. The summer mode icon on the main control panel will activate and remain active for as long as the summer mode timer is on. Following this
8-hour period, the circulation pump, heater, and ozone will continue to turn off for an 8-hour period every day that the Summer Mode timer is on. The continual 8-hour
shutdown minimizes the amount of heat transferred to the spa water. When the outside temperatures begin to cool, the Summer Mode timer should be turned to the OFF
position (the summer mode icon on the main control panel shuts off). This is the efficient 24-hour circulation mode that keeps the heater operation and operating costs to
a minimum during colder/heavier usage months.