Watkins CalderaSpas Utopia Series Owner's Manual - Versassage
VersassaGe
®
anD OrBIssaGe
®
JeT MaInTenanCe
If you notice that the VersaSsage or OrbiSsage jet spins slower than when the spa was new, or the jets are sticking, the cause may be built-up deposits inside the jet
bearings. To remove the deposits, use the following instructions:
With the spa off, rotate the VersaSsage/OrbiSsage jet face counter-clockwise until it stops.
1.
Once the face stops rotating, use a little extra force to rotate the face even more counter-clockwise past the locking position until it stops. Pull face with the body
2.
away from the spa.
After flushing the bearing inside the body with water, spin the rotating eye. It should spin very freely. If it does not, place the bearing end in a cup of vinegar (the
3.
vinegar will soften any deposits). Allow it to soak overnight. The next day, flush with water and repeat the spin test.
NOTE: If it still doesn’t spin freely, a second night of soaking is required. If the bearing still does not spin, you will need to purchase a replacement assembly from
your Caldera
®
dealer.
TO reMOVe anD rePlaCe a FaCe PlaTe:
To remove a VersaSsage/OrbiSsage face plate, turn the plate counter-clockwise until it stops turning.
1.
Turn the face plate once more until you hear a clicking noise, push it in, and then pull it straight off.
2.
Install the new face plate by snapping it into place. The VersaSsage/OrbiSsage jet should spin freely when you turn the jet pump on.
3.
DraInInG YOur sPa
Turn off all GFCI breakers in sub-panel, or main electrical panel.
1.
Locate the main drain valve for the spa. Pull on handle (Figure
2.
1) until you reach the mid position then rotate handle slightly to
fully extended drain tube (drain cap and 1” of the drain tube is
exposed) (Figure 2) then remove the drain cap (Figure 3).
NOTE: You will not be able to remove drain cap in mid position.
Attach the garden hose to the end of the drain (to avoid flooding
of the foundation surrounding the spa) making sure not to
push the drain tube inward. Route the outlet of the hose to an
appropriate draining area).
NOTE: Spa water with a high sanitizer level may harm plants
and grass.
Push the garden hose and drain tube half-way back towards
3.
the spa (Figure 4) which will start the gravitational flow. Drain
tube must be in the mid position for the spa to drain.
IMPORTANT: All models will drain almost completely through
the drain valve. Equipment such as the jet pump and heating
system may not completely drain. Any water remaining within the plumbing or equipment after draining will only need to be removed if the spa is being winterized.
After your spa is empty, clean the shell and filter cartridge.
4.
Pull and remove garden hose, replace drain cap and push drain tube back into spa as seen in Step 1.
5.
Follow the “START-UP AND REFILL PROCEDURES” to refill your spa.
6.
PreVenTIOn OF FreeZInG
Your spa has been designed and engineered for year-round use in any climate. In some areas, extremely cold temperatures (below 10°F) combined with strong
wind, may cause partial freezing of the jet pump, even though the water inside the spa remains at the selected temperature. The energy efficiency of the spa may
also decrease during these cold periods, as the heater will cycle more frequently. As an additional precaution against partial freezing of some of the components, the
equipment compartment can be insulated with an insulating kit (available from your local dealer). This insulating kit will also help to maximize the spa’s energy efficiency.
NOTE: When warmer weather returns (approx. 60°-70°F), the insulating kit must be removed to prevent overheating of the jet pump.
wInTerIZInG YOur sPa
If you leave the spa unused for a long period of time in severely cold weather, you should drain the spa and winterize it to avoid accidental freezing due to a power or
equipment failure. Follow the directions on the next page.
DANGER: Use only Propylene Glycol as your anti-freeze (available at most RV or marine supply stores). This is non-toxic. Never use an automobile anti-freeze
(Ethylene Glycol) since it is toxic!
WARNING: Failure to follow these instructions correctly can lead to freeze damage not covered by warranty. It is strongly recommended that you contact your local
dealer to perform this service.
35
MAINTENANCE
DRAIN
Figure 1
Handle
Figure 2
Figure 3
Drain Cap
with
Handle
Garden
Hose
Drain
Tube
Figure 4