Webasto Diesel Cooker x100 Operating And Maintenance Manual - Webasto Diesel Cooker X100
6 / ENGLISH
Webasto Diesel Cooker X100
Yellow
Yellow
Yellow
0.125 s
0.125 s
0.125 s
0.125 s
0.125 s 0.125 s
0.125 s 0.125 s 0.125 s
0.125 s 0.125 s 0.125 s
0.125 s 0.125 s 0.125 s
2 s
2 s
2 s
2 s
2 s
2 s
0.25 s
0.25 s
0.25 s
0.25 s ...
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Glow plug
problem
Combustion
air fan
problem
Cooling
air fan
problem
Under-
voltage
Yellow
Yellow
Red
Red
Red
30s
30s
0.125s
0.125s
0.25s
0.25s
0.25s
0.25s
0.125 s 0.125 s 0.125 s 0.125 s ...
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Locking
after 2
unsuccessful
starts.
Overheat
Lights after
failure
signal
Opening the locking:
1. Switch the power ON (lock blinking).
2. Disconnect the main power cord (blinking stops).
3. Reconnect the main power cord (the yellow LED lights up for 1-3
seconds).
4. When the yellow LED has gone out, switch the power OFF.
The red lamp begins blinking when failure signal has lasted for 5
minutes.
3.3 Signal lights in
case of malfunctions
In case of malfunctioning the
yellow and red lamps on the
operating panel indicate a
possible failure type.
Depending on the failure
type please check the
following:
1. Are the batteries
sufficiently charged? The
stove needs at least 10.7 V
for the start up.
2. Does the fuel hose carry
fuel?
3. Is the cooling air fan
running freely without
blockage?
4. Does the cooling fan get
enough air from inside the
vehicle?
If the cooker still does not
start after a restart, you
should contact an authorized
Webasto service centre for
assistance.
Figure 4: Signal lights in case of malfunctions.
0.125 s 0.125 s
0.125 s 0.125 s
In the enent of long lasting heavy smoke development, unusual
combustion noises or a smell of fuel or if the cooker suffers continuous
fault cutouts with error messages, it must be put out of service by
removing the fuse and must not be reused until it has been inspected by
an authorized Webasto centre.