Webasto Thermo Call TC2 COMFORT Installation Manual - page 9
Thermo Call TC2
13
Installation with digital
timer
Thermo Call TC2 can be operated together
with a Webasto digital timer.
- Disconnect 4-pole connector from
digital timer
- Connect the main cable harness of
the Thermo Call TC2 to the digital
timer and the 4-pin plug of the
additional heating cable harness.
NOTE:
The Thermo Call TC2 must be
parameterised to the digital timer in the
programming menu.
Installation with Telestart
T91 / T100 HTM
Thermo Call TC2 always has to be the first
control element after the auxiliary
heater.Both Telestart and any digital timer
must be connected after this.
Please use the special Y-Adapter when
installing Thermo Call at systems where
Telestart is already installed (see Webasto
accessory catalogue). This is additionally
available as a Webasto original
accessory.Please also note the selection of
cable and antenna adapter accessories.
Connection of S/W-line
In addition to the work described in the
installation instructions for Thermo Call
TC2, the following steps must also be
performed, using the included materials.
The corresponding technological principles
must be observed during installation.
- If the purple wire (5) is connected to a
summer / winter switch, pull this off
and disconnect the existing plug.
to the digital
timer
Timer
connector
To the special Y-Adapter
Connector
control element
1
2
3
4
5