Weber Vieluxe Slide-In Dual Burner Station Installation Manual

Other manuals for Vieluxe Slide-In Dual Burner Station: Installation Manual, Owner's Manual, Owner's Manual
Manual is about: Model 36251, Model 37251, Liquid Propane Dual Burner Station

Summary of Vieluxe Slide-In Dual Burner Station

  • Page 1

    Clearance from combustible surfaces or structures warning: clearance from any surface or structure is 26 inches from the back and sides of the burner station. Refer to “typical gas supply installation” before starting installation. Locating your side burner when determining a suitable location for y...

  • Page 2

    2 built-in structure cutout dimensions warning: all countertop finished surfaces must be constructed of a noncombustible material. Countertop burner station all dimensions are to finished surfaces. Countertop burner station tolerances a 28 3 ⁄ 4 " b 8 3 ⁄ 4 " c 22 1 ⁄ 2 " + 1 ⁄ 4 - 1 ⁄ 4 + 1 ⁄ 4 - 1...

  • Page 3: Built-In Gas Line Locations

    Slide-in burner station tolerances a 4” b 7” c 2 1 ⁄ 2 ” + 1 ⁄ 16 - 1 ⁄ 16 + 1 ⁄ 16 - 1 ⁄ 16 + 1 ⁄ 16 - 1 ⁄ 16 3 3 built-in gas line locations a c b front view front of burner station structure plan view area should be kept clear of sharp, jagged, or extremely abrasive surfaces to avoid possible dam...

  • Page 4: Typical Gas Supply

    4 caution: if young children are in the area, a locking valve should be considered. ■ pipe compound should be used which is resistant to the action of natural gas when gas connections are made. ■ the gas connections must be firmly attached to rigid, permanent construction. Note: the information prov...

  • Page 5: Typical Gas Supply

    5 gas line piping (continued) ■ copper tubing must be tin-lined if the gas contains more than 0.3 grams of hydrogen sulfide per 100 cubic feet of gas. ■ plastic tubing is suitable only for outdoor, underground use. ■ gas piping in contact with earth, or any other material which may corrode the pipin...

  • Page 6: Slide-In Burner

    6 gas line adjustable feet burner station frame foot fully extended and secured foot not fully extended slide-in burner station installation caution: use two people to lift and install the vieluxe ® slide-in burner station. 1) lift the burner station out of the packaging. 2) make sure that the adjus...

  • Page 7: Countertop Burner

    7 countertop burner station installation gas line burner station frame burner station frame "island" structure countertop caution: use two people to lift and install the vieluxe ® countertop burner station. 1) lift the burner station out of the packaging. 2) push the burner station into the “island”...

  • Page 8: Ventilation

    8 or view of right side view of left side front view back view or warning: air holes must be provided in the structure at the top and bottom to provide ventilation in the event of a gas leak. Air holes can be located in a low visibility area and should be protected by screening material to prevent r...