Weber Vieluxe Slide-In Dual Burner Station Installation Manual - Ventilation
8
OR
View of Right Side
View of Left Side
Front View
Back View
OR
WARNING: Air holes must be provided in the
structure at the top and bottom to provide
ventilation in the event of a gas leak.
Air holes can be located in a low visibility area and should
be protected by screening material to prevent rodents and
insects from entering the structure. Air holes will also help
dry moisture.
Vieluxe
®
cabinet vents (#61429) are available from your
dealer or call Vieluxe
®
Customer Service at
1-866-VIELUXE.
■ Cross ventilation must be incorporated in the
supporting structure. We recommend a minimum of
100 square inches of venting per side.
■ Vents should be on two sides of the structure.
The above drawings are for reference only.
■ Location of the vents should be from the center,
outward.
■ Locate the vents at both the bottom of the structure
and at the top of the structure.
■ The bottom vents should be as close to ground level
as possible. Make sure the vent area is not blocked
by interior supports of the structure.
■ We recommend vents with screens.
■ Access doors to the structure are not considered vents.
■ Clean the vents periodically.
DANGER: Failure to follow recommended minimum
venting instructions can cause gas to collect in the
structure in the event of a gas leak. This may result
in a fire or an explosion which can cause serious
bodily injury or death, and damage to property.
VENTILATION
Front View
Back View
OR
© 2004 Weber-Stephen Product Co.. Vieluxe
®
is a registered U.S. trademark of Weber-Stephen Products Co.,
200 East Daniels Road, Palatine, IL 60067-6266. U.S.A. 1-866-VIELUXE.
Once your burner station has been set into place and the
adjustable feet have be set to level your station to the
"island" structure countertop, install the floor panel.
SLIDE-IN FLOOR PANEL
INSTALLATION
Slide-In Burner Station
The floor panel will fit over the top of the adjustable feet.