Wood Master 3300 Installation, Operating And Maintenance Manual - Factory Settings
19
Woodmaster Owner’s Manual
August 2012
E.T.C. Reference
(Fig. 2)
(Fig. 6)
(Fig. 5)
(Fig. 4)
(Fig. 3)
(Fig. 1)
WoodMaster Digital Aqua Stat Settings
Set Point (SP)
170
°
F
76.7
° C
Differential (HY)
10
°
F
5.5
° C
Low Alarm (ALL)
120
°
F
48.9
° C
Factory Settings
WoodMaster Digital Aqua Stat Minimum and Maxi
-
mum Settings
Set Point (SP)
100° F to 180° F
38° C to 82° C
Differential (HY)
1° F to 45° F
1° C to 25° C
Low Alarm (ALL)
-67° F to 302°
F
-55° C to 150° C
Caution!!
Do not set your (SP) lower than your (ALL)!
Changing E.T.C. Settings
For units equipped with the XR30C
Changing the Set Point
1. Press and hold the set button for 3 seconds or until the fan symbol is
flashing. The number that appeared is the Set Point. (Fig. 1)
2. Use the up or down arrow buttons to adjust the setting.
3. Press the set button to lock in the setting.
Changing the Hy
1. Press and hold the arrow down and set buttons until the display
reads Hy. (Fig. 2)
2. Release the arrow down and set buttons.
3. Press set button, the number displayed is the differential. (Fig. 3)
4. Press the arrow up or down button to adjust. (Fig. 4)
5. Press the set button. (Fig. 5)
6. The display will read ALL for approximately 30 seconds, it will
then return to the water temperature reading. (Fig. 6)
Changing the ALL
1. When the ETC reads ALL from the previous step, press the set
button. The number that appears is the Low Alarm temperature.
2. To adjust the number press the up or down arrow.
3. Press the Set button to lock in the setting.
Definitions
Set Point
- The temperature at which the fan will shut down.
Hy
aka
Differential
- The amount, in degrees, the temperature has to
drop in order to start the fan.
ALL
- aka
Low Alarm
- The temperature at which the furnace will
shut down.
Note: The procedures are the same wether you are using degrees (F) or degrees (C).