3300 Slab Dimensions
5500 Slab Dimensions
6500 Slab Dimensions
4400 Slab Dimensions
Technical Specifications
& Slab Dimensions
3300
4400
5500
6500
Specification
Water Capacity
105 Gallons
487 Gallons
194 Gallons
117 Gallons
Heating Capacity
20,000 sq. ft.
1
2000 sq. ft.
1
Amp. Draw
@ 120v AC, 60 Hz
Max- 19.8 Amp
Idle- .5 Amp
Avg. Running- 6.41
5000 sq. ft.
1
10,000 sq. ft.
1
Firebox Dimensions
34” x 32”
60” x 58”
50” x 56”
38” x 44”
Loading Door Opening
Outside Dimensions
20” x 21”
44” x 31”
27” x 27”
Weight of Furnace filled
with water
2292 lb.
7789 lb.
4450 lb.
2784 lb.
24” x 24”
*
Amp draw may vary depending on the revision of your furnace and external devices attached to your furnace.
Maximum Amp Draw can only occur when all devices are operating, this only happens momentarily at the start up.
1
Actual results will vary depending on the system, applications and insulation values.
Max- 7.5 Amp
Idle- .5 Amp
Avg. Running- 3.5
Max- 6.9 Amp
Idle- .5 Amp
Avg. Running- 2.5
Max- 6 Amp
Idle- .5 Amp
Avg. Running- 1.5
*
*
*
*