Cautionary Notes on Use
De-Ashing
To ensure that the stove will not over fire whilst the ashpit door is open, we would strongly recommend that de-ashing
is only undertaken when the fuel load is almost exhausted, the stove is out or in a very low state. Furthermore, once
the riddling has been complete it is essential to fully open the main fire door prior to opening the ashpit door.
Maximum Temperature - Over-firing the Stove - Use Beyond the Rated Output
The stove body is designed to run up to a maximum temperature not exceeding 700F or 400C (the stove
firedoors must be kept shut at all times except when re-fuelling or de-ashing the stove). We recommend the use
of a stove thermometer available from your dealer or us.
There are 5 possible causes for stoves over-heating :-
1
After de-ashing as above, incorrect relocation of ashpit door and/or primary air vents left open.
2
The 4 levelling bolts supplied not fitted in their holes in the corners of the base of the stove (under the
ashpan).
3
The ashpit door or fire door rope seals worn or damaged or missing. They should be replaced if necessary or
they can be pulled out, adjusted and easily re-placed in their channels. No fixative is needed.
4
Check that the rope seal between the stove body and its canopy is in position.
5
Excessive chimney draw (the minimum flue draft for nominal heat output is:- not exceeding 0.15 mbar (0.06"
water gauge)). If it is high use remedial action; either the fitting of a flue stabiliser to the flue as close to the ap-
pliance as is aesthetically possible, the fitting of a flue damper in the chimney, or a chimney cowl. (Ask
your dealer or contact us for
details).
Chipboard and other composite wood-type materials contain corrosive additives, as do sulphurous coal prod-
ucts especially when mixed with wet wood, that may etch and permanently damage the surface of the glass.
A reminder to the installer.
All the split saddle boilers are two physically separate boilers that must be linked at the rear of the stove and tee'd off to
the flow and return pipes.
The Boiler circuit should have an Inhibitor added to it.
REGULATIONS AND INSTALLATION INSTRUCTIONS
FOR THE WOODWARM FIREVIEW STOVES
All local regulations, including those referring to national and European Standards (BS 6461, Installation of
chimneys and flues for domestic appliances burning solid fuel (including wood and peat) & BS 8303, Code of
practice for installation of domestic heating and cooking appliances burning solid mineral fuel) need to be
complied with when installing this appliance.
Health and Safety at Work
It is the responsibility of the installer to comply with current Health and Safety Regulations, and particular attention
should be given to the following:-
Asbestos
This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of installation then
please seek specialist guidance and use appropriate protective equipment.
Handling
This stove is heavy and adequate facilities must be available for all handling operations and its final manoeuvre into
position. In order to lighten the stove, the main door may be removed. The baffle and grate bars can also be removed.
Glass
Care should be taken when handling the door that the glass is not knocked. The door is double glazed.
Fire Cement
Some types of Fire Cement are caustic and should not be allowed to come into contact with the skin. In cases of con-
tact, wash off with plenty of water.
Electrical
If any electrical components are used in the installation they should be installed in accordance with the manufacturers
installation instructions and all wiring must comply with the current I.E.E regulations and the by-laws of the local water
authority.
Air Supply
Building Regulations dictate that an air vent of some type (usually an air brick) must be fitted into an exterior wall to al-
low sufficient flow of air into the fire. Air Inlet grills must be so positioned that they are not liable to blockage.
This stove should not be fitted in a room where an extractor fan is in use, as this could result in flue reversal and the
emission of flue gases into the room.
HEARTH
The stove must stand on a fireproof hearth which must be at least 127mm thick and constructed of a