Xantech XVCE100IR Installation Instructions Manual - Xvce100Ir Rj45
FIGURE 1 shows the most basic connection. A power supply must
be connected to the XVCE100IR. The credit card remote (included)
can still be used. However, no IR bus is established to control
source components.
The 781RG Power Supply should be connected to the XVCE100IR
Volume Control as follows.
XVCE100IR RJ45
781RG POWER SUPPLY
PIN 6 (White/Green)
+12VDC
PIN 8 (Brown)
GROUND
Installation Tip – Setting the Volume
1) Set your receiver and/or amplifier to the lowest possible
volume setting.
2) Turn the XVCE100IR volume control to maximum volume
(press up arrow).
3) Turn up the receiver and/or amplifier volume setting until you
reach the maximum listening level desired.
4) Finally, lower the XVCE100IR volume control level (press
down arrow). Volume setting is now complete.