Deleting All Temporary And Permanent Fingerprints
(Requires Master User authorization)
1.
Press the FUNC key, and the 6/DEL ALL PRINTS key.
2.
Input MF, or input MC and the ENTER key.
3. If the Master User authorization was successful, the ACCEPT LED will
flash, followed by all of the LEDs flashing simultaneously.
4. Press the ENTER key to confirm deletion of all fingerprints. (NOTE: MF
will not be deleted)
5. Perform i-touch™ / Autocloser™ synchronization procedure.
NOTE: Master may wish to remove all fingerprint users’ information
from the User ID / Fingerprint User table at the back of this manual.
Adding a Temporary Access Code
(Requires Master User authorization)
A Temporary Access Code is set to expire after a user specified number of
days. To input a temporary access code:
1.
Press the FUNC key, then the 7/TEMPORARY key, followed by the 4/
ADD CODE key.
2.
Input MF, or input MC and the ENTER key. If the Master User Authoriza-
tion is successful, the ACCEPT LED will flash.
3.
The INPUT LED should be lit solid. Enter a 4-6 digit temporary access
code followed by the ENTER key. The INPUT LED will remain on.
4.
Enter the number of active days (max 30 days), followed by the ENTER
key. The temporary code will expire in the number of active days (+/- two
hours).
5. If the temporary access code addition was successful, the ACCEPT LED
will flash. If the ERROR LED flashes, an incorrect code was input or the
input timed out.
6. If finished with the batch of code additions, perform i-touch™ / Auto-
closer™ synchronization procedure.