Xpresskit CANMAX400 Installation Manual - page 5
Rev.: 20101015
Platform: CANMAX400
Firmware: GM10
© 2010 Directed Electronics. All rights reserved.
Vehicle Canbus Integration System
Page 5
*Default Option
Features
Operation
Option
No RF Output
RFTD Output
Disabled
Enabled*
OFF*
ON
3
RF output type
Activate this feature whenever an external RFTD
module is used (i.e.: XL201 or XL202)
1
2
Tach Output (W2W only)
Unlock Driver Priority
Feature and Option List
To enter feature programming routine
Accessing another feature
Once a feature is programmed
For vehicles that are not Push-to-Start (PTS), use the key to turn the ignition ON, then OFF. For PTS vehicles, press the button
twice to turn the ignition ON, then press it once more to turn it OFF.
Within 5 sec, press and HOLD the integrated programming button (IPB). The orange LED turns ON after 3 seconds. Release the
IPB.
The green LED starts flashing slowly one time to indicate the feature number is 1. After a short delay, the red LED flashes rapidly
one time to indicate the current option of feature 1. It repeats until next action happens.
Press and release the IPB a number of times to advance from the current feature to the next desired
.
The green LED flashes slowly the number of times equal to the feature number. After a short delay, the red LED flashes rapidly a
number of times to indicate the current option of the current feature. It repeats until next action happens.
Another feature(s) can be programmed.
The feature programming can be exited.
When the maximum number of feature or option is reached, the LED will start flashing again from the first feature or option.
-
-
-
-
-
-
-
Changing feature options
-
-
Press the lock/arm or unlock/disarm button on aftermarket transmitter to change the option of the selected feature.
The red LED flashes rapidly the number of times equal to the current option number. After a short delay, the green LED flashes
slowly the number of times to indicate the current feature. It repeats until next action happens.
feature
Exiting feature programming
-
-
No activity for 30 seconds; after 30 seconds, the orange LED will turn ON for 2 seconds to confirm exiting.
OR
Press and HOLD the IPB for 3 seconds. After 3 seconds, the orange LED will turn ON for 2 seconds to confirm exiting.
Feature Programming
Integrated
Programming
Button (IPB)