Zadako Z1 User Manual - Reporting Alarm Status
Reporting alarm status
Alarm status can be triggered by following means:
•
internal detector of motion / inclination
sensor of motion and inclination is a part of device, and in case of move or inclination
detection it trigers alarm
•
external signal inputs
•
External signal inputs can be connected to door contacts, (circuit protection), to
sensors of glass break, or to any other sensor. Car alarm has two external inputs.
They react to connecting to negative pole (ground) of supply. On cable harness,
there are following colors of conductors used fro external inputs:
•
white – yellow external alarm input 1 - active permanently
•
white – blue external alarm input 2 - active only when arming switched on, this
input is also delayed, that means alarm will be generated after arrival time is over
(see setting of PC). It means, that if you disarm before this time is over, there will be
no alarm
Additional info:
•
when arming is switched on and external horn is set ( REL=ALARM ) the
horn will be active maximum 10 times from alarm trigger ,
•
after total number of 10 alarms is reached within one arming, other alarms
from external input 2 will not be registered ; external alarm 1 as well as other
motion detector will continue triggering alarms ( sending SMS and calling ),
external alarm, registered at input 1 while arming switched off does not
activate external horn ( with setting REL=ALARM ).
•
at REL=ALARM relay signalize by sound beep arming - 2x short beep and
disarming – 1x short beep
When arming is activated, alarm can be triggered by:
1.Car movement in any direction
2.Activation of external input nr. 1 (connecting to negative pole (ground) of supply)
3.Activation of external input nr. 2 (connecting to negative pole (ground) of supply)
When arming is deactivated, alarm can be evoked by:
4.Activation of external input nr. 1 (connecting to negative pole (ground) of supply)
12