3Com EtherLink 3C985B-SX Installation And User Manual - page 29
Checking the Port LEDs
25
7 Review the test results.
The test result from the previous example could look like the following:
Both the internal and external loopback example tests show 1000 packets successfully received with 0 errors
detected, indicating that the NIC hardware is functioning properly.
If the NIC does not perform as expected, try reinstalling the NIC card or moving it to a different slot or to a different
system, then run the DOS Diagnostics tests again. If the card still fails, contact 3Com Customer Support.
Checking the Port LEDs
1000Base-SX Fiber NICs
Two port LEDs are located on the faceplate of the 1000Base-SX NIC: one to indicate link status and one for data
transfer status (see "1000Base-SX Fiber NICs" on page 9). Before the port LEDs can provide troubleshooting
information, the NIC must be connected to the network (see Chapter 2), and the network drivers for your
particular operating system must be installed (see Chapter 3).
Log file created by Development and Diagnostic Test Program v2.3.1
on: Thu Apr 6 10:20:46 2000
---------------------------------------------
Development and Diagnostic Test Program ( ) v2.3.1
PCI bios found. v0.16.
HW Mech #1 supported
Number of PCI buses: 1
3Com #0 found in PCI bus 0.
1 3Com card(s) detected
Current card set to bus 0 3Com #0.
internal Loopback Test
pkts:0 secs:0pkts:32 secs:1pkts:144 secs:2pkts:256 secs:3pkts:352
secs:4pkts:480 secs:5pkts:576 secs:6pkts:704 secs:7pkts:800
secs:8pkts:912 secs:9 1000 packets transmitted successfully
1000 packets received successfully
0 errors detected
external Loopback Test
pkts:0 secs:0pkts:96 secs:1pkts:208 secs:2pkts:320 secs:3pkts:432
secs:4pkts:544 secs:5pkts:656 secs:6pkts:768 secs:7pkts:880
secs:8pkts:992 secs:9 1000 packets transmitted successfully
1000 packets received successfully
0 errors detected
>