3M Accuspray Owner's Manual - page 9
8
General Set Up and Spray Gun Use cont.
Spray Gun Identification
Attach color clips into the groove on the fan and fluid
adjustment knobs, to identify the application of the spray
gun use
Example of attaching air flow control valve:
1 Manually attach the air flow control valve to the air inlet
by hand threading the connection
2 Use two wrenches to connect the air flow control valve
Adjust to fit the air inlet and adjust the other to fit the
air flow control valve then tighten the connection
Setting the Air Pressure
Pull trigger back (fluid and air/full trigger pull) and adjust
operating pressure to read 20 psi (1 4 bar) for optimum
spray performance
Adding the PPS™ Components
3
To facilitate measurement of materials to be sprayed
according to manufacturer’s guidelines, place the
3M™ PPS™ Mix Ratio Film Insert into the 3M™
PPS™ mixing cup
4
Insert the 3M™ PPS™ liner into the 3M™ PPS™
mixing cup
5
Pour material to be sprayed into the 3M™ PPS™
mixing cup Stir as needed
6
Place the 3M™ PPS™ lid with built-in filter on top
of the 3M™ PPS™ mixing cup with liner and snap
into place
PDF Scaled at 100.0%