4xem WLPTZ User Manual - page 87
- 83 -
http://<servername>/cgi-bin/setdo.cgi?do1=
[&do3=
Where state is H, L. H means NC (normal close) connected with COMMON and L
means NO (normal open) connected with COMMON. The number of DO dependents
on the server type.
parameter Value
description
H – NC connected with COMMON
do
L – NO connected with COMMON
return
Redirect to the page
parameter is assigned. The
be a full URL path or relative path according the
the current path. If you omit this parameter, it
will redirect to an empty page.
Example: Drive the digital output 1 to high and redirect to an empty page
http://myserver/cgi-bin/setdo.cgi?do1=H
Query Status of the Digital Input
Note: This request requires the privilege of I/O access control.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/getdi.cgi?[di1][&di2][&di3][&di4]
If no parameter is specified, all the status of digital input will be returned.
Return:
HTTP/1.0 200 OK\r\n
Content-Type: image/jpeg\r\n