A&D MC-2000 Instruction Manual - page 10
MC-2000, Version 2.6
I:MAN-MC2000USA
9
F7 – $1 Coin Addition (Factory setting is “on”)
With “F7” on display, press
TOTAL. Display shows “51 on”. Press ROLLS to turn off, (dis-
play then shows “51 off”), then press
Enter to save.
F8 – Automatic Add to Totalizer (Factory setting is “on”)
With “F8” on display, press
TOTAL. Display shows “Ad on”. Press ROLLS to turn off, (dis-
play shows “Ad off”), then press
Enter to save.
F9 – Automatic Coin Cup Tare (Factory setting is “on”)
With “F9” on display, press
TOTAL. Display shows “tA on”. The Factory setting adjusts for
the weight of the coin scoop provided with your MC-2000. To adjust for another container,
press
Enter, display then shows “Zero”. Place empty coins scoop or cup to be used, then
press
ZERO. Then press Enter to save.
To disable the tare entirely: when display shows “tA on”, press
ROLLS, (display then shows
“tA off”), then press
Enter to save.
F10 – Maximum Bill Prompt (Factory setting is “on”)
With “F10” on display, press
TOTAL. Display shows “40”. Selections are 40 / 50 / 60 / 80 /
100 / 150 / OFF / 20 / 30. Press
BILLS to increase, press TOTAL to decrease. Press Enter
to save.
RS-232C Connection
MC-2000 has an RS-232C output for connection to a printer or computer. A&D offers Model
AD-1191 Printer which comes equipped with time & date and interface cable. The RS-232C
data is factory set at 2400 baud, 7 data bits, even parity, 1 stop bit.
Pin No.
Pin Name
3
Transmit Data
Signal Level
RS-232
5
Signal Ground
RS-232
3
5
Front View
Pin assignments for the DSUB9 serial port connector