Error Codes
MESSAGE
MEANING / POSSIBLE SOLUTION
pppppp
A weight greater than 5 lb. has been applied to the MC-2000. Remove the weight from
the platter. Try re-calibrating the scale if this doesn’t solve the problem. Otherwise, pos-
sible load cell damage due to overloading.
Lo
Sample weight – used only in counting mode - is too low. More samples required.
“Err 2”
During calibration, the test weight placed on the platter is too light. If this does not solve
the problem, then there is possible load cell damage due to overloading or some other
internal problem.
Setup Functions
Your MC-2000 is basically ready to use right out of the box. There are, however, certain user setup &
support functions which allow adjustments best suited to your personal needs:
WE STRONGLY RECOMMEND YOU USE YOUR MC-2000 FOR A FEW DAYS,
BEFORE YOU DECIDE TO CHANGE ANY FACTORY SETTINGS.
FUNCTION
FACTORY
DESCRIPTION
F1
N/a
Calibration: There is no need to calibrate the MC-2000 unless you feel
that the scale has become inaccurate.
F2
N/a
Initialize all Factory Settings (F1-F10): Resets all factory settings.
F3
ON
Auto Currency Advance: Factory setting for money counting program
automatically advances through each denomination as money removed
from MC-2000.
F4
OFF
Auto Power Off: If using AC adapter, we recommend that you leave the
scale on at all times. If using batteries, change F4 to “ON”. MC-2000 will
turn itself off after 10 minutes of non-activity to preserve battery life.
F5
See Chart-
Below
Re-initialize Average Piece Weight (APW) Factory Settings (F6 only).
This is a simple method for restoring your initial factory settings of average
piece weights for all denominations.
F6
N/a
Monetary Average Piece Weight (APW) Adjustment: If you determine
that your scale is inaccurately counting all denonimations, you should re-
calibrate (F1). If, however, you determine that the scale is okay on most
denominations, but consistently light/heavy on one particular denomina-
tion, you do not need to calibrate, simply adjust the apw for that particular
denomination.
F7
ON
$1 Coin: enables/disables$1 coins and $1 coin roll mode.
F8
ON
Automatic Add to Totalizer: eliminates the need to press ADD button.
Monetary value will be added immediately upon removal of money (&/or)
scoop from the scale.
F9
ON
Automatic Coin Cup Tare: Eliminates the need to “zero” the coin scoop
(standard accessory) or optional coin cups (purchased separately).
F10
ON
Maximum Bill Prompt: Restricts placing more than 40 bills on the scale
at one time, ensuring maximum bill count accuracy. This setting can be
turned off or value can be changed. Choices are: 40 / 50 / 60 / 80 / 100 /
150 / OFF / 20 / 30.