    Content 1. Access device 3 1.1. Description of outline in standard configuration . . . . . . . . . . . . . . . . . . . 3 1.2. Characteristic parameters of a-gear p1004t epon system . . . . . . . . . . . . 5 1.3. Rohs description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 3: Access Device

    1. Access device this chapter mainly describes and introduces overall characteristics and parameters of a-gear p1004t epon access device so that readers can get an overall understanding about a-gear p1004t epon. 1.1. Description of outline in standard configuration a-gear p1004t epon interface consi...

  • Page 4

    Figure 1-2. Back panel view of a-gear p1004t epon. Table 1-3. Description of leds on back panel of a-gear p1004t epon led lamp code quantity color status description power lamp 1 green off onu is not switched on on onu normally switched on, pon lamp 1 green off indicating that onu does not complete ...

  • Page 5

    1.2. Characteristic parameters of a-gear p1004t epon system protocol standard supporting standard ieee std 802.3-2005 ieee std 802.1d-2004 ieee std 802.1q-2005 technical requirement for china telecom epon equipment yd/t 1475-2006 hardware characteristics memory flash memory: 4m bytes; psram: 2mbytes...

  • Page 6: Installation Preparation

    2. Installation preparation 2.1. Precautions for use similar to other electronic products, quickly and frequently turning on/off power supply will damage semi-conductor chip. When you need to re-start a-gear p1004t epon, please turn on power switch again 3~5 seconds after it is switched off. Please ...

  • Page 7

    • cause short circuit or damage to the elements. • before operation on the equipment, cut off dc power supply. • improper connection between equipment and power sockets may cause hazard. • only those trained, qualified personnel can carry out operation and maintenance • on the equipment. • before th...

  • Page 8

    2.3.3. Rack configuration the following content helps you design a suitable rack configuration. • each equipment on the rack will emit heat during working. To ensure good ventilation, closed rack must be provided with heat dispersion port and cooling fan, and equipment should be closely placed from ...

  • Page 9

    3. Installation of a-gear p1004t epon warning: only those trained, qualified personnel can install or replace the equipment. 3.1. A-gear p1004t epon installation flow start preparatory works install at specified location connect the cable checkup power on configure over 3.2. Epon access device insta...

  • Page 10

    3.3. Connecting ports 3.3.1. Gepon sff optical port a-gear p1004t epon provides 1 gepon sff port. Indicator lamps corresponding to this port are pon and loss. During use, connect sc optical fibre to the port, and then to optical splitter and then from optical splitter to olt equipment. 3.3.2. Ethern...

  • Page 11

    3.4. Check after installation after mechanical installation of epon access device is completed, please make the following check before starting epon access device: • if epon access device is mounted on vertical wall surface, please check the installation reliability of epon access device. It install...

  • Page 12: Analysis of Hardware Failure

    Disassembly of the equipment may require some tools, which are not included in standard configuration of epon access device. These tools are as follows: • cross screwdriver • anti-static hand ring pleas open the cover of epon access device according to the following steps. (1) pull off power cable o...

  • Page 13

    • if power supply is normal for a certain circuit of epon access device, the power indicator lamp power should be lit, otherwise power supply for this circuit is abnormal. When the system is normally registered on olt, pon lamp should be lit and los lamp should be off. 5.1.2. Failure in port, cable ...