A-gear P1004T EPON Hardware Installation Manual - page 7
•
cause short circuit or damage to the elements.
•
Before operation on the equipment, cut off DC power supply.
•
Improper connection between equipment and power sockets may cause hazard.
•
Only those trained, qualified personnel can carry out operation and maintenance
•
on the equipment.
•
Before the system is switched on, please carefully read installation guide.
Note:
[1]
Carefully observe potential hazard, such as damp floor, non-grounded power
[2]
extension cable, worn power cable
[3]
Place the emergency switch in the workroom so that power can be rapidly cut
[4]
off when accident occurs
[5]
Before installation/disassembly of the equipment, pull off the power cable
[6]
Please do not work independently if there is potential hazard
[7]
Before check, always cut off power supply
[8]
If accident occurs, please take the following measures
[a]
Switch off the system
[b] Give alarm
[c] Judge whether the affected person needs [artificial respiration or not, and then take proper measures
[d] Where possible, send a possible to seek for medical help; otherwise seek for help according to serious degree
2.3.
General Requirements for Location
This part discusses the requirements for the location of safe installation and use of the
system. Before installation, ensure that the location has been properly prepared.
2.3.1.
Environment of the Location
By adoption of card-track installation method, EPON access device can be fixed on DIN card
track. The equipment adopts fan-free design. Please note that installation environment
should be well-ventilated to facilitate equipment heat dispersion.
When planning location arrangement and equipment placement, please remember to
discuss the precautions as set forth in «Precautions for Allocation of the Location». If the
equipment often breaks down or error often occurs, such precaution information may help
you isolate failure and avoid recurrence of the problem.
2.3.2.
Precautions for Allocation of the Location
Precautions listed below may help you design a suitable environment for EPON access
device to avoid system failure caused by the environment.
•
Ensure air is well circulated and electrical equipment heat is well dispersed in the work
room. Air circulation must be sufficient to provide a good cooling environment;
•
Equipment should be better placed in such a way that cool air frequently passes by the
equipment. Ensure the outer casing of the equipment is complete and fixed. If it is open,
air circulation inside the equipment will be damaged, which may interrupt airflow or
change the direction of the cool air that should cool down heat-emitting the internal
elements.