AAdynTech Punch Series Light User Manual - page 11
11
•
RECALL SETTING
•
The software shall present individually fifteen choices to the user: PRESET1, PRESET2,
PRESET3, and CUSTOM1 through CUSTOM12 changing the choice each time a right
or left arrow button is pressed. The CUSTOM settings are described below.
•
The PRESET settings shall be hard coded into the software and not changeable by the
user. Preset values are described below.
•
When the user presses the select (green check) button, the software shall set these
parameters with the saved settings from a CUSTOM or a PRESET, given the profile the
user has chosen:
o LIGHT CONTROL
o UIM BRIGHTNESS
o UIM FADE
o UIM EFFECT SELECTION
o UIM EFFECT FREQUENCY
o DMX BASE ADDRESS
o DMX CHANNEL MODE
•
The factory default for the RECALL SETTING parameter shall be PRESET1.
•
SAVE CUSTOM
•
The software shall present individually twelve choices to the user: CUSTOM1 through
CUSTOM12 changing the choice each time the right or left arrow button is pressed.
•
When the custom setting is selected (green check button) by the user, the software shall
save these parameters to non-volatile memory:
•
LIGHT CONTROL
•
UIM BRIGHTNESS
•
UIM FADE
•
UIM EFFECT SELECTION
•
UIM EFFECT FREQUENCY
•
DMX BASE ADDRESS
•
DMX CHANNEL MODE
•
The factory default for the SAVE CUSTOM parameter shall be CUSTOM1.
•
MODEL NAME
•
Current model names:
!
Punch Plus
!
Tungsten
•
SOFTWARE VERSION
•
The software shall maintain and display the software version.
•
RECALIBRATION PT
•
The software shall start at 25000 hours and count down to zero and then count
negatively if necessary to let the user know it is time to have the LED’s replaced. The
time shall count down based on hours of continuous use at a particular brightness
setting.
•
UIM FADE parameter:
•
Values from 0 to 100 percent that can be incremented or decremented in steps of 0.3,
0.7 and 1.0 on slow scroll. Medium and medium fast shall scroll by one and fast shall
scroll by five.
•
Each setting value shall represent a delay in the increase or decrease of the UIM
BRIGHTNESS parameter.