12
•
0 shall indicate that the UIM BRIGHTNESS parameter change is to occur immediately
and 100 percent shall introduce a three second delay in changing the current parameter
value to the requested value.
•
At power on, the value of UIM FADE shall default to 0 percent if there is no power on
profile.
•
The factory default for the UIM FADE parameter shall be 0%.
•
The UIM FADE parameter is only active when UIM EFFECT is set to NONE (OFF).
•
UIM EFFECT SELECT
•
The software shall present individually thirteen choices for the UIM EFFECT SELECT
parameter:
•
NONE (OFF) – Turn off any current effect
•
STROBE,
•
LIGHTNING1 SGL,
•
LIGHTNING1 RPT,
•
LIGHTNING2 SGL,
•
LIGHTNING2 RPT,
•
LIGHTNING3 SGL,
•
LIGHTNING3 RPT,
•
LIGHTNING4 SGL,
•
LIGHTNING4 RPT,
•
LIGHTNING5 SGL,
•
LIGHTNING5 RPT,
•
LIGHTNING CYCL
•
The choice shall change by one each time a right or left arrow button is pressed.
•
STROBE shall make the LEDs emit pulses of light at a 30 percent on / 70 percent off
duty cycle and that are of a user designated frequency and brightness. These
parameters are UIM EFFECT FREQUENCY and UIM BRIGHTNESS.
•
LIGHTNINGx SGL shall make the LEDs emit pulses of varied length and brightness
based on internal parameters to simulate a lightning strike. SGL indicates that this
sequence shall be shown only once each time the Enter Key is pressed. The length and
brightness components of lightning shall be defined in the software. There shall be five
different sequences of lightning defined and designated by a number where the x is
located.
•
LIGHTNINGx RPT shall make the LEDs emit pulses of varied length and brightness
based on internal parameters to simulate a lightning strike. RPT indicates that this
sequence shall be shown repeatedly, with each sequence separated by a two second
off interval. The length and brightness components of lightning shall be defined in the
software. The same five single sequences defined above shall be used for the repeat
lightning.
•
LIGHTNING CYCL shall show each sequence in order with each sequence separated
by a two second off interval. At the end of the fifth sequence, the process shall be
repeated.
•
If a LIGHTNING effect has been started, it shall be completed even if the user disables
effects during the sequence.
•
At power on, the UIM EFFECT SELECT shall default to NONE(OFF) if there is no power
on profile.
•
The factory default for the UIM EFFECT SELECT shall be NONE.
•
UIM EFFECT FREQUENCY
•
Values from 0 to 100 percent that can be incremented or decremented in steps of 0.3,
0.7 and 1.0 on slow scroll. Medium and medium fast shall scroll by one and fast shall
scroll by five.
•
Each setting value shall represent how quickly the lightning and strobe effects operate.
Higher numbers represent a slower effect.