AAdynTech Punch Series Light User Manual - 1. Functional Requirements
9
1. Functional Requirements
The AAdyn Punch light is controlled by software (embedded firmware). In general the software shall control the
light and accept user inputs from multiple device types. Via the user inputs the light may be controlled and
various parameters may be saved in non-volatile memory.
The software shall monitor input from the following:
•
CIM – an AAdyn proprietary Control Interface Module
•
UIM – an AAdyn proprietary User Interface Module.
•
DMX – a unidirectional digital network based on the DMX512 standard.
•
Cancel (X) – which also referred to as the douse button, is a button that shuts off the light while it is
pressed.
The following sections provide all of the functional requirements for the AAdyn Punch Light Series.
1.1. Proprietary Control/User Interface Module Requirements
Note: Operation of the integral Control Interface Module (CIM) is identical to that of the User Interface
Module (UIM)
•
The CIM/UIM Remote Interface Controller has a backlit LCD display that the software shall control
and six user input keys. The keys shall provide the following functionality:
• UP/DOWN keys – select the parameter to be controlled.
• LEFT/RIGHT keys – adjust the value of the selected parameter.
• CHECKMARK (Enter) key – some parameters are only put into effect after the enter key is
pressed. It also causes savable values to be stored.
• Red ‘X’ (UIM remote douse) – shall cause the light to be extinguished while it is pressed.
•
The software shall display a menu of parameters on the UIM controller. The parameters listed below
shall be displayed in the order shown from top to bottom when the down key is pressed and shall
default to LIGHT CONTROL. When the up key is pressed the order will proceed from LIGHT
CONTROL to the bottom of the list, then upwards.
•
LIGHT CONTROL
•
UIM BRIGHTNESS
•
UIM FADE
•
UIM EFFECT SELECT
•
UIM EFFECT FREQUENCY
•
DMX BASE ADDRESS
•
DMX CHANNEL MODE
•
WIRELESS SHOW ID
•
MODEL NAME / SW VERSION / SN# / LIGHT UNIQUE ID / RADIO SW
RECALIBRATION HOURS / RESET FACTORY DEFAULT
•
POWER ON SETTING
•
SAVE CUSTOM
•
RECALL SETTING
•
Under each parameter, the software shall present settings pertaining to the parameter for the user to
select. The settings shall be:
•
POWER ON SETTING