Summary of BDI2000

  • Page 1

    Bdipro ® for cpu16/32/32+ user manual manual version 1.12 for bdi2000 © 1993-2001 abatron ag.

  • Page 2

    Bdipro for bdi2000 (cpu16/32/32+) user manual 2 © copyright 1993-2001 by abatron ag v 1.12 1 introduction ................................................................................................................................. 3 1.1 bdi2000......................................................

  • Page 3

    Bdipro for bdi2000 (cpu16/32/32+) user manual 3 © copyright 1993-2001 by abatron ag v 1.12 1 introduction bdipro is a powerful software package, allowing on-board programming with the bdi2000 from abatron. Bdipro eliminates the inefficient, individual chip programming, particularly for surface- moun...

  • Page 4

    Bdipro for bdi2000 (cpu16/32/32+) user manual 4 © copyright 1993-2001 by abatron ag v 1.12 1.2 functions the bdipro software provides the following functions: file load/save • save and recall user defined program sets print • print the active program set print preview • display the active program se...

  • Page 5

    Bdipro for bdi2000 (cpu16/32/32+) user manual 5 © copyright 1993-2001 by abatron ag v 1.12 2 installation 2.1 connecting the bdi2000 to target the cable to the target system is a ten pin flat ribbon cable. In case where the target system has an appropriate connector, the cable can be directly connec...

  • Page 6

    Bdipro for bdi2000 (cpu16/32/32+) user manual 6 © copyright 1993-2001 by abatron ag v 1.12 bdi main / target a connector signals: all the pins except pin 1need to be connected to the target system for the programming operation. Pin name describtion 1 --- not used. 2 berr bus error active-low input t...

  • Page 7

    Bdipro for bdi2000 (cpu16/32/32+) user manual 7 © copyright 1993-2001 by abatron ag v 1.12 2.1.1 changing target processor type before you can use the bdi2000 with an other target processor type (e.G. Cpu32 ppc), a new setup has to be done (see appendix a). During this process the target cable must ...

  • Page 8

    Bdipro for bdi2000 (cpu16/32/32+) user manual 8 © copyright 1993-2001 by abatron ag v 1.12 2.2 connecting the bdi2000 to power supply 2.2.1 external power supply the bdi2000 needs to be supplied with 5 volts (max. 1a) via the bdi option connector (rev. A) or via power connector (rev. B/c). The avail...

  • Page 9

    Bdipro for bdi2000 (cpu16/32/32+) user manual 9 © copyright 1993-2001 by abatron ag v 1.12 2.2.2 power supply from target system the bdi2000 needs to be supplied with 5 volts (max. 1a) via bdi main target connector (rev. A) or via target a connector (rev. B/c). This mode can only be used when the ta...

  • Page 10

    Bdipro for bdi2000 (cpu16/32/32+) user manual 10 © copyright 1993-2001 by abatron ag v 1.12 2.3 status led «mode» the built in led indicates the following bdi states: mode led bdi states off the bdi is ready for use, the firmware is already loaded. On the power supply for the bdi2000 is blink the bd...

  • Page 11

    Bdipro for bdi2000 (cpu16/32/32+) user manual 11 © copyright 1993-2001 by abatron ag v 1.12 2.4 connecting the bdi2000 to host 2.4.1 serial line communication the host is connected to the bdi through the serial interface (com1...Com4). The communication cable between bdi and host is a serial cable (...

  • Page 12

    Bdipro for bdi2000 (cpu16/32/32+) user manual 12 © copyright 1993-2001 by abatron ag v 1.12 2.4.2 ethernet communication the bdi2000 has a built-in 10 base-t ethernet interface (see figure below). Connect an utp (un- shilded twisted pair) cable to the bd2000. For thin ethernet coaxial networks you c...

  • Page 13

    Bdipro for bdi2000 (cpu16/32/32+) user manual 13 © copyright 1993-2001 by abatron ag v 1.12 2.5 installation of the bdipro software on the enclosed diskette you will find the bdipro software and the firmware required for the bdi. Copy all the files of the desired diskette to a directory on your hard...

  • Page 14

    Bdipro for bdi2000 (cpu16/32/32+) user manual 14 © copyright 1993-2001 by abatron ag v 1.12 2.6.1 bdi2000 setup/update first make sure that the bdi is properly connected (see chapter 2.1 to 2.4). The bdi must be con- nected via rs232 to the windows host. To avoid data line conflicts, the bdi2000 mus...

  • Page 15

    Bdipro for bdi2000 (cpu16/32/32+) user manual 15 © copyright 1993-2001 by abatron ag v 1.12 subnet mask enter the subnet mask of the network where the bdi is connected to. Use the following format: xxx.Xxx.Xxx.Xxxe.G.255.255.255.0 a subnet mask of 255.255.255.255 disables the gateway feature. Ask yo...

  • Page 16

    Bdipro for bdi2000 (cpu16/32/32+) user manual 16 © copyright 1993-2001 by abatron ag v 1.12 3 specifications operating voltage limiting 5 vdc ± 0.25 v power supply current typ. 500 ma max. 1000 ma rs232 interface: baud rates 9’600,19’200, 38’400, 57’600,115’200 data bits 8 parity bits none stop bits...

  • Page 17

    Bdipro for bdi2000 (cpu16/32/32+) user manual 17 © copyright 1993-2001 by abatron ag v 1.12 4 environmental notice disposal of the equipment must be carried out at a designated disposal site. 5 declaration of conformity (ce).

  • Page 18

    Bdipro for bdi2000 (cpu16/32/32+) user manual 18 © copyright 1993-2001 by abatron ag v 1.12 6 warranty abatron switzerland warrants the physical diskette, cable, bdi2000 and physical documentation to be free of defects in materials and workmanship for a period of 24 months following the date of purc...

  • Page 19: Appendices

    Bdipro for bdi2000 (cpu16/32/32+) user manual 19 © copyright 1993-2001 by abatron ag v 1.12 appendices a troubleshooting problem the firmware can not be loaded. Possible reasons • the bdi is not correctly connected with the target system (see chapter 2). • the power supply of the target system is sw...

  • Page 20

    Bdipro for bdi2000 (cpu16/32/32+) user manual 20 © copyright 1993-2001 by abatron ag v 1.12 b maintenance the bdi needs no special maintenance. Clean the housing with a mild detergent only. Solvents such as gasoline may damage it. If the bdi is connected correctly and it is still not responding, the...

  • Page 21

    Bdipro for bdi2000 (cpu16/32/32+) user manual 21 © copyright 1993-2001 by abatron ag v 1.12 observe precautions for handling (electrostatic sensitive device) unplug the cables before opening the cover. Use exact fuse replacement (microfuse msf 1.6 af). 4 5 4.1 while holding the casing, slide careful...

  • Page 22

    Bdipro for bdi2000 (cpu16/32/32+) user manual 22 © copyright 1993-2001 by abatron ag v 1.12 c trademarks all trademarks are property of their respective holders..