Summary of COM600 series

  • Page 1

    Com600 series, version 4.1 snmp opc server user's manual.

  • Page 3

    Contents: 1. About this manual .................................................................................. 5 1.1. Copyright ........................................................................................ 5 1.2. Disclaimer .................................................................

  • Page 4

    3.4.7.4. Single point status (sps) for opc internal data ............................................................ 25 3.4.8. Configuring data objects for snmp device .................. 26 3.4.8.1. General about configuring data objects for snmp device ................................................

  • Page 5: About This Manual

    About this manual 1. Copyright 1.1. This document and parts thereof must not be reproduced or copied without written per- mission from abb, and the contents thereof must not be imparted to a third party, nor used for any unauthorized purpose. The software or hardware described in this document is fu...

  • Page 6: Conformity

    Be responsible or liable for any loss or damage resulting from the use of this manual or the application of the equipment. Conformity 1.3. This product complies with the directive of the council of the european communities on the approximation of the laws of the member states relating to electromagn...

  • Page 7: Document Conventions

    Operation this section covers the basic operation procedures you can carry out when transferring or activating grid automation controller com600 (later referred to as com600) with new configurations. Document conventions 1.6. The following conventions are used for the presentation of material: • the...

  • Page 8: Terminology

    The electrical warning icon indicates the presence of a hazard which could result in electrical shock. The warning icon indicates the presence of a hazard which could result in personal injury. The caution icon indicates important information or warning related to the concept discussed in the text. ...

  • Page 9: Abbreviations

    Description term a physical iec 61850 device that behaves as its own commu- nication node in the iec 61850 protocol. Intelligent electronic device representation of a group of functions. Each function is defined as a logical node. A physical device consists of one or several lds. Logical device; ld ...

  • Page 10

    Description abbreviation international electrotechnical commission iec intelligent electronic device ied lon application guideline for substation automation lag local area network lan logical device ld lonmark interoperable device communicating in lonworks network. In this document, the term is used...

  • Page 11: Related Documents

    Related documents 1.10. Mrs number name of the manual 1mrs756125 com600 user's manual document revisions 1.11. History product revision document version/date document created 3.5 a/30.6.2011 document revised 4.0 b/31.5.2012 document revised 4.1 c/13.3.2015 11 com600 series, version 4.1 1mrs757276 sn...

  • Page 12: Introduction

    Introduction 2. General about the com600 series 2.1. The com600 series comprises of substation management units that are deployed together with protection and control relays and other communication devices, such as relion® protection and control relays and remote i/o units, to realize smart substati...

  • Page 13: Snmp Opc Server Features

    Snmp_overview.Png figure 2.2-1 system overview 1. Ncc (network control center) 2. Com600 with snmp opc server 3. Station automation builder 600 (sab600) 4. Snmp compliant network switch 5. Protection and control devices snmp opc server features 2.3. The snmp opc server is intended for providing meth...

  • Page 14: Configuration

    Configuration 3. About this section 3.1. This section guides you in the configuration tasks required before you can start using the snmp opc server. For information on the iec 61850 data modeling, refer to com600 user's manual. Start sab600 to open a project. You can also open and name a new project...

  • Page 15

    Example_view.Png figure 3.2-1 example view of sab600 the configuration work can basically be divided into two separate tasks: 1. Building an object tree, and 2. Configuring object properties. First, you need to build an object tree. This is done by adding objects to the object tree, see 3.3.1, gener...

  • Page 16: Building Object Tree

    Description object an object representing a network device that supports snmp protocol. Snmp ied an object representing a group of functions. Each function is defined as a logical node. A device consists of one or several lds. Snmp opc logical device (ld) an object defined by its data and methods. L...

  • Page 17

    Adding snmp opc server object 3.3.3. After the gateway object has successfully been added, you can continue building the object tree by adding an snmp opc server object. To add an snmp opc server object: 1. Select the gateway object in the communication structure and right-click it. 2. Select new > ...

  • Page 18: Configuring Objects

    The new preconfigured objects appear in the object tree. If the configuration file is large, the import may take time. To import a configuration file for a different device, right- click the device, select scl import again and repeat the steps above. For more information about the scl import functio...

  • Page 19

    To configure an object: 1. Select an object in the object tree of the communication structure. • the object properties appear now in the object properties window. The proper- ties and their values can be viewed as shown in figure 3.4.1-1. Snmp_object_properties_example figure 3.4.1-1 example of obje...

  • Page 20

    Configuring snmp subnetwork properties 3.4.3. The snmp opc server subnetwork properties that can be configured and value ranges for them can be found in table 3.4.3-1. The actual configuration by using sab600 is performed as described in 3.4.1, general about configuring objects. Table 3.4.3-1 snmp s...

  • Page 21

    Description value or value range/ default property/para- meter community name defined on the network device. Community name is used to authenticate snmp packets, which must match the community name that is spe- cified on the agent. Public community name community name used for the writing operation....

  • Page 22

    Description value or value range/ default property/para- meter station/remote switch opc path opc path of the station remote switch position to be used with this device. The format is node#progid for opc server#channel name\ied name\logical device name\logical node name\data object name e.G. Gw#abb....

  • Page 23

    Description value or value range/ default property/parameter logical node class. Ancr, arco, atcc, avco, lphd, calh, ccgr, cilo, cpow, cswi, gapc, ggio, gsal, iarc, ihmi, itci, itmi, mdif, mhai, mhan, mmtr, mmxn, mmxu, msqi, msta, pdif, pdir, pdis, pdop, pdup, pfrc, phar, phiz, pioc, pmri, pmss, pop...

  • Page 24

    Integer status (ins) for opc internal data 3.4.7.2. Table 3.4.7.2-1 configurable ins (for opc internal data) properties for opc servers description value or value range/ default property/para- meter basic common data class according to iec 61850 ins common data class addresses item tag path for the ...

  • Page 25

    Description value or value range/ default property/para- meter item tag path for the internal status information. The internal server tags that can be used are located in the attributes nodes that are located under the root, line and ied nodes. When an attribute tag is referred to in the internal it...

  • Page 26

    Configuring data objects for snmp device 3.4.8. General about configuring data objects for snmp device 3.4.8.1. Object identifiers (oids) are used in data object configuration. Each oid identifies a variable that can be read or set via snmp. The snmp device uses a hierarchical namespace management i...

  • Page 27

    Description value or value range/ default property/ para- meter serial number text string describing the serial number. Abb123456789 serial number location textstring describing the location. Vaasa location table 3.4.8.2-2 configurable dpl properties for snmp opc server, subtype read from device des...

  • Page 28

    Description value or value range/ default /example property/para- meter snmp object identifier (oid) of the man- aged object. 1.3.6.1.2.1.25 object identifier scale and unit scale for output. Lookup table scale stepwise linear scale default: none output scale scale for status. Lookup table scale ste...

  • Page 29

    Logical node name plate (lpl) 3.4.8.5. Table 3.4.8.5-1 configurable lpl properties for snmp opc server, subtype basic description value or value range/ default /example property/para- meter basic common data class according to iec 61850. Lpl common data class object subtype. Basic sub type vendor a ...

  • Page 30

    Description value or value range/ default /example property/para- meter snmp object identifier (oid) of the man- aged object. 1.3.6.1.2.1.25 object identifier scale and unit specifies the multiplier for current si unit. Yocto, zepto, atto, femto, pico, nano, micro, milli, centi, deci, no multiplier,...

  • Page 31

    Description value or value range/ default /example property/para- meter si unit for measurement as described in iec61850. Meter, kilogram, second, ampere, kelvin, mole, candela, degrees, radian, steradian, gray (j/kg), becquerel (l/s), degrees (celsius), sievert (j/kg), farad, coulomb, siemens, henr...

  • Page 32

    Description value or value range/ default /example property/para- meter object identifier snmp object identifier (oid) of the man- aged object. 1.3.6.1.2.1.25 object identifier scale and unit specifies the multiplier for current si unit. Yocto, zepto, atto, femto, pico, nano, micro, milli, centi, de...

  • Page 33

    Description value or value range/ default /example property/para- meter si unit for measurement as described in iec61850. Meter, kilogram, second, ampere, kelvin, mole, candela, degrees, radian, steradian, gray (j/kg), becquerel (l/s), degrees (celsius), sievert (j/kg), farad, coulomb, siemens, henr...

  • Page 34

    Controllable single point (spc) 3.4.8.7. Table 3.4.8.7-1 configurable spc properties for opc servers with snmp device, subtype basic description value or value range/ default /example property/para- meter basic common data class according to iec61850 spc common data class object subtype bit mask def...

  • Page 35

    Description value or value range/ default /example property/para- meter scale for output. Lookup table scale stepwise linear scale default: none output scale scale for status. Lookup table scale stepwise linear scale default: none scale single point status (sps) 3.4.8.8. Table 3.4.8.8-1 configurable...

  • Page 36

    Description value or value range/ default property/para- meter bit mask for the value. 0 to 65535 default: 1 bit mask scale and unit scale to be used with this type. Lookup table scale stepwise linear scale default: none scale binary counter reading (bcr) 3.4.8.9. Table 3.4.8.9-1 configuring bcr pro...

  • Page 37: Operation

    Operation 4. About this section 4.1. This section describes the basic operation procedures you can carry out after the been configured. After this, you can, for example, monitor and control the condition of connections in network. This is done by using the online diagnostics function in sab600. Acti...

  • Page 38: 4.4.

    Snmp_event_log.Png figure 4.3-2 event log file ext_event_log_file.Png figure 4.3-3 event log file diagnostic ae client diagnostic events can be monitored and controlled using the diagnostic ae client function. Click refresh to update the status information. To be able to receive events from a certai...

  • Page 39: Data Object Diagnostics

    • in the status information field, you can monitor the device status. • the diagnostic counters field provides information on device activity. To reset diagnostic counters, click reset counters. • take the snmp device into use by selecting the in use check box. If you clear the check box, the device...

  • Page 40

    40

  • Page 41: Index

    Index a adding data object ..................................................................................................... 18 gateway object ............................................................................................... 16 logical device ..........................................

  • Page 42

    L logical device adding ........................................................................................................... 18 logical device properties ....................................................................................................... 22 logical node adding ...............

  • Page 43

    Subnetwork .................................................................................................... 17 subnetwork snmp ............................................................................................................ 17 43 com600 series, version 4.1 1mrs757276 snmp opc server ...

  • Page 44

    44.

  • Page 46

    Contact us 1mrs757276 c/13.3.2015 © copyright 2015 abb. All rights reserved. Abb oy distribution automation p.O. Box 699 fi-65101 vaasa, finland tel. +358 10 22 11 fax. +358 10 224 1094 abb inc. Distribution automation 655 century point lake mary, fl 32746, usa tel: +1 407 732 2000 fax: +1 407 732 2...