Summary of COM600 series

  • Page 1

    — com600 series, version 5.0 dnp 3.0 serial master (opc) user's manual.

  • Page 3

    Contents: 1. About this manual .................................................................................. 7 1.1. Copyright ........................................................................................ 7 1.2. Disclaimer .................................................................

  • Page 4

    3.4.7.3. Controllable single point (spc) for opc internal data ................................................ 28 3.4.7.4. Single point status (sps) ........................... 29 3.4.8. Configuring data objects ............................................... 29 3.4.8.1. General information about c...

  • Page 5

    5.2.9. Controllable double point (dpc) ................................... 58 5.2.10. Device name plate (dpl) .............................................. 59 5.2.11. Double point status (dps) ............................................ 59 5.2.12. Controllable integer status (inc) ...................

  • Page 6

    6.

  • Page 7: About This Manual

    About this manual 1. Copyright 1.1. This document and parts thereof must not be reproduced or copied without written per- mission from abb, and the contents thereof must not be imparted to a third party, nor used for any unauthorized purpose. The software or hardware described in this document is fu...

  • Page 8: Conformity

    Be responsible or liable for any loss or damage resulting from the use of this manual or the application of the equipment. Conformity 1.3. This product complies with the directive of the council of the european communities on the approximation of the laws of the member states relating to electromagn...

  • Page 9: Document Conventions

    Operation this section covers the basic operation procedures you can carry out when transferring or activating grid automation controller com600 (later referred to as com600) with new configurations. You are also given instructions on how to monitor and control the conditions of dnp 3.0 network. Doc...

  • Page 10: Terminology

    The electrical warning icon indicates the presence of a hazard which could result in electrical shock. The warning icon indicates the presence of a hazard which could result in personal injury. The caution icon indicates important information or warning related to the concept discussed in the text. ...

  • Page 11: Abbreviations

    Description term change of process data or an opc internal value. Normally, an event consists of value, quality, and timestamp. Event a physical iec 61850 device that behaves as its own commu- nication node in the iec 61850 protocol. Intelligent electronic device representation of a group of functio...

  • Page 12: Related Documents

    Description abbreviation programmable logic controller plc program organization unit pou request to send rts substation automation sa substation configuration description scd substation configuration language scl sequential function chart sfc single line diagram sld extended markup language xml rela...

  • Page 13: Introduction

    Introduction 2. General information about the com600 series 2.1. The com600 product series are versatile substation management units that help realize smart substation and grid automation solutions in industrial and utility distribution net- works. They get deployed together with protection and cont...

  • Page 14: Functional Overview

    • com600f is a dedicated distribution automation controller unit that runs dis- tributed grid and feeder applications for ansi power networks and inherits all core features of the com600 series. Functional overview 2.3. The dnp opc server provides methods for opc clients to exchange data with device...

  • Page 15: Configuration

    Configuration 3. About this section 3.1. This section guides you in the configuration tasks required before you can start using the dnp opc server. For information on the iec 61850 data modeling, refer to com600 user's manual. Start station automation builder 600 (later referred to as sab600). Then ...

  • Page 16: Building Object Tree

    In the object tree communication view, you can see the dnp opc server object and its child objects such as channels, devices, and data objects. After you have added the necessary objects to the object tree in the communication structure, configure them, see 3.4.1, general information about configuri...

  • Page 17

    Adding dnp opc server object 3.3.3. After the gateway object has successfully been added, you can continue building the object tree by adding dnp opc server object. To add dnp opc server object: 1. Select the gateway object in the communication structure and right-click it. 2. Add dnp opc server obj...

  • Page 18

    With scl import function, you can import new objects with configurations from an existing file. Right-click the device and select scl import from the shortcut menu. To import a new configuration file: 1. Click choose file. 2. Browse to a new configuration file from the appearing dialog. 3. Select th...

  • Page 19: Configuring Objects

    Configuring objects 3.4. General information about configuring objects 3.4.1. After the objects have been added, configure the object properties. Figure 3.4.1-1 shows an example of how to use sab600 to configure the object properties for dnp opc server. To configure an object: 1. Select an object in...

  • Page 20

    Configuring dnp opc server properties 3.4.2. Table 3.4.2-1 dnp opc server properties description value or value range/default property/parameter basic instance identification of dia- gnostic opc alarm and event server. Ae prog id instance identification of dia- gnostic opc data access server. Da pro...

  • Page 21

    Description value or value range/default property/parameter transmission rate used on the line. 300 bits/s 600 bits/s 1200 bits/s 2400 bits/s 4800 bits/s 9600 bits/s 19200 bits/s 38400 bits/s 56000 bits/s 115200 bits/s 128000 bits/s 256000 bits/s default: 19200 bits/s bit rate serial port used by th...

  • Page 22

    Description value or value range/default property/parameter defines of collision detection is in use or not. Carrier detection not in use carrier detection in use default: carrier detection not in use collision detection time delay in milliseconds between the activation of the rts signal and the sta...

  • Page 23

    Description value or value range/default property/parameter specifies if only one application layer command (e.G. Poll) may be active at any time. Enabling this configuration is useful when the communication hard- ware does not support collision detection. The poll intervals defined with the topic c...

  • Page 24

    Configuring dnp serial device 3.4.4. Table 3.4.4-1 configuring dnp serial device properties description value or value range / default name basic diagnostics enabled true false default: false diagnostics enabled controls whether the device communication is initially in use or not. In use not in use ...

  • Page 25

    Description value or value range / default name length of pulse, in milli- seconds, used in the output commands of the control relay. 0 to 65535 default: 0 pulse length off for control relay output block length of pulse, in milli- seconds, used in the output commands of the control relay. 0 to 65535...

  • Page 26

    Description value or value range / default name defines application level con- firmation handling. Default: disable process data confirmation lengths maximum number of retries of an application data fragment. 0 to 5 default: 5 application message data retries length of data object address used in dn...

  • Page 27

    Description value or value range/ default property/parameter logical node class ancr, arco, atcc, avco, lphd, calh, ccgr, cilo, cpow, cswi, gapc, ggio, gsal, iarc, ihmi, itci, itmi, mdif, mhai, mhan, mmtr, mmxn, mmxu, msqi, msta, pdif, pdir, pdis, pdop, pdup, pfrc, phar, phiz, pioc, pmri, pmss, popf...

  • Page 28

    Integer status (ins) 3.4.7.2. Table 3.4.7.2-1 description value or value range/ default property/para- meter basic common data class according to iec 61850 ins common data class addresses item tag path for the internal status information. The internal server tags that can be used are located in the ...

  • Page 29

    Single point status (sps) 3.4.7.4. Table 3.4.7.4-1 configurable sps (for opc internal data) properties for opc servers description value or value range/ default property/para- meter basic common data class according to iec 61850 sps common data class addresses item tag path for the internal status i...

  • Page 30

    Description value or value range/ default property/ para- meter general index 0...65535 default: 0 general index neutral index 0...65535 default: 0 neutral index phase a index 0...65535 default: 0 phase a index phase b index 0...65535 default: 0 phase b index phase c index 0...65535 default: 0 phase...

  • Page 31

    Description value or value range/ default property/ para- meter specifies the type of the timestamp a message is sent with. Send as static data (always without time) event without time event with time event with relative time (valid for binary inputs only) default: event with time time and type vari...

  • Page 32

    Description value or value range/ default property/ para- meter data class spe- cific object number for indication. Binary input (1, 2) binary output (10) default: binary input (1, 2) indication object defines if all changes in value are sent to the master. True false default: false send all updates...

  • Page 33

    Description value or value range/ default property/ para- meter indication index. -1…65535 default: -1 indication index data class spe- cific object number for control. Default: analog control output block (41). Control object variation for control. Default: 2 control variation object number for ind...

  • Page 34

    Binary controlled step position information (bsc) 3.4.8.6. Table 3.4.8.6-1 configurable bsc properties description value or value range/ default property/ parameter basic common data class according to iec 61850. Bsc common data class addresses control index. -1 to 65535 default: -1 control index in...

  • Page 35

    Description value or value range/ default property/ para- meter sub-type mv sub-type simple subtype data class spe- cific object number for indication. Analog input (30, 32) analog output (40) default: analog input (30, 32) indication object scale and unit specifies the multiplier for current si uni...

  • Page 36

    Delta (del) 3.4.8.8. Table 3.4.8.8-1 configurable del properties description value or value range/ default property/ para- meter basic common data class according to iec 61850. Del common data class addresses phase ab index -1 to 65535 default: -1 phase ab index phase bc index -1 to 65535 default: -...

  • Page 37

    Description value or value range/ default property/ para- meter high-high limit for measurement. Event is created when value crosses the limit. Default: 0 high-high low limit for measurement. Event is cre- ated when value crosses the limit. Default: 0 low low-low limit for measurement. Event is crea...

  • Page 38

    Description value or value range/ default property/ para- meter defines if all changes in value are sent to the master. True false default: false send all updates defines if the value of a message is inverse. True false default: false send as inverse value defines if a value is sent as single point....

  • Page 39

    Double point status (dps) 3.4.8.11. Table 3.4.8.11-1 configurable dps properties for opc client description value or value range/ default property/ para- meter basic common data class according to iec 61850. Dps common data class addresses indication index. 0...65535 default: 0 indication index comm...

  • Page 40

    Description value or value range/ default property/ para- meter specifies the type of the timestamp a message is sent with. Send as static data (always without time) event without time event with time event with relative time (valid for binary inputs only) default: event with time time and type vari...

  • Page 41

    Integer status (ins) 3.4.8.13. Table 3.4.8.13-1 configurable ins properties description value or value range/ default property/ para- meter basic common data class according to iec 61850. Ins common data class addresses index. -1 to 65535 default: -1 index data class spe- cific object number for ind...

  • Page 42

    Measured value (mv) 3.4.8.15. Table 3.4.8.15-1 configurable mv properties description value or value range/ default property/ para- meter basic common data class according to iec 61850. Mv common data class addresses indication index. -1 to 65535 default: -1 index sub-type mv sub-type simple subtype...

  • Page 43

    Description value or value range/ default property/ para- meter high-high limit for measurement. Event is created when value crosses the limit. Default: 0 high-high low limit for measurement. Event is cre- ated when value crosses the limit. Default: 0 low low-low limit for measurement. Event is crea...

  • Page 44

    Description value or value range/ default property/ para- meter defines if all changes in value are sent to the master. True false default: false send all updates defines if a value is sent as double point. True false default: false send as double point defines if the value of a message is inverse. ...

  • Page 45

    Description value or value range/ default property/ para- meter maximum update rate of signal state changes between the opc server and client in milliseconds. 0 means that the server sends all the changes to the client. 0...65535 default: 0 update rate data class spe- cific object number for indicat...

  • Page 46

    Description value or value range/ default property/ para- meter subtype of wye wye simple subtype addresses neutral index -1 to 65535 default: -1 neutral index phase a index -1 to 65535 default: -1 phase a index phase b index -1 to 65535 default: -1 phase b index phase c index -1 to 65535 default: -...

  • Page 47

    Description value or value range/ default property/ para- meter specifies the multiplier for the current si unit. Default: deka net multiplier scale for net used with this data object. Default: none net scale unit for net. Default: dimensionless net unit specified the number of decimals shown in hsi...

  • Page 48

    Description value or value range/ default property/ para- meter high-high limit for measurement. Event is created when value crosses the limit. Default: 0 high-high low limit for measurement. Event is cre- ated when value crosses the limit. Default: 0 low low-low limit for measurement. Event is crea...

  • Page 49: Topic Generator

    Topic generator 3.5. When the data objects have been configured with the dnp data objects, use the dnp topic generator function to specify how the data is requested from the dnp device. To create a topic: 1. Click the communication tab on the left. 2. Right-click the dnp ied and select the dnp topic...

  • Page 50

    To add an event poll topic, specify the polling interval in hundreds of millisecond and the number of events to poll (value 0 = all events). If you want to poll all events every 1 s, set up as shown in the add topic dialog. Sab600_dnp_serial_topic_generator_eventpoll.Png figure 3.5-2 add event poll ...

  • Page 51

    Sab600_dnp_serial_modify_topic.Png figure 3.5-4 modify an existing topic to delete a topic: 1. In topic generator tool, select whole row of the topic you want to delete. 2. Press the delete key from the keyboard to delete the topic. Sab600_dnp_serial_delete_topic.Png figure 3.5-5 delete a topic 51 c...

  • Page 52: Operation

    Operation 4. About this section 4.1. This section describes the basic operation procedures you can carry out after the server has been configured. After reading this section, you can, for example, monitor and control network connections. Monitoring and controling is done by using the online diagnost...

  • Page 53: Dnp Channel Diagnostics

    Dnp channel diagnostics 4.4. The dnp channel activity can be monitored with the online diagnostics function. You can also take a channel into use or out of use as described in this section. To monitor and control dnp channel activity: 1. Select the channel you want to monitor in the object tree of s...

  • Page 54: Technical Reference

    Technical reference 5. About this section 5.1. This section provides reference information about the following issues: • iec 61850 data modeling • attributes • status codes iec 61850 data modeling 5.2. General information about iec 61850 data modeling 5.2.1. The relationship between the iec 61850 da...

  • Page 57

    Delta (del) 5.2.8. Opc data types dnp information element mandat- ory/optional value/value range type name vt_r4 vt_i4 vt_date vt_i4 vt_r4 vt_r4 vt_r4 vt_r4 vt_r4 vt_r4 vt_i4 vt_i4 vt_bstr phase ab current value on-line, com lost server provided if none separate signal separate signal separate signa...

  • Page 58

    Opc data types dnp information element mandat- ory/optional value/value range type name vt_r4 vt_i4 vt_date vt_i4 vt_r4 vt_r4 vt_r4 vt_r4 vt_r4 vt_r4 vt_i4 vt_i4 vt_bstr phase ca current value on-line, com lost - separate signal separate signal separate signal separate signal separate signal separat...

  • Page 59

    Device name plate (dpl) 5.2.10. Opc data types dnp data object field mandat- ory/optional value/value range type name vt_bstr - m visiblestring vendor vt_bstr - o visiblestring hwrevision vt_bstr - o visiblestring swrevision vt_bstr - o visiblestring sernum vt_bstr - o visiblestring location double ...

  • Page 62

    Opc data types dnp data object field mandat- ory/optional value/value range type name vt_r4 - o real max vt_i4 config o integer siunit vt_i4 config o integer multiplier vt_bstr config o string unit vt_i4 config o integer numofdec vt_i4 - o range range controllable single point (spc) 5.2.19. Opc data...

  • Page 63

    Wye 5.2.21. Opc data types dnp information element mandat- ory/optional value/value range type name vt_r4 vt_i4 vt_date vt_i4 vt_r4 vt_r4 vt_r4 vt_r4 vt_r4 vt_r4 vt_i4 vt_i4 vt_bstr phase a current value on-line, com lost – separate signal separate signal separate signal separate signal separate sig...

  • Page 64

    Opc data types dnp information element mandat- ory/optional value/value range type name vt_r4 vt_i4 vt_date vt_i4 vt_r4 vt_r4 vt_r4 vt_r4 vt_r4 vt_r4 vt_i4 vt_i4 vt_bstr phase c current value on-line, com lost – separate signal separate signal separate signal separate signal separate signal separate...

  • Page 65

    Opc data types dnp information element mandat- ory/optional value/value range type name vt_r4 vt_r4 vt_date vt_r4 vt_r4 vt_r4 vt_r4 vt_r4 vt_r4 vt_r4 vt_r4 vt_r4 vt_bstr net current value online, com lost - separate signal separate signal separate signal separate signal separate signal separate sign...

  • Page 66: Appendix 1

    Appendix 1 device profile table a1-1 the device profile describing the implementation of the dnp 3.0 master protocol in com600 dnp 3.0 device profile document vendor name: abb oy distribution automation device name: com600 3.4 device function: [x] master [ ] slave highest dnp level supported: for re...

  • Page 67

    Requires data link layer confirmation: [ ] never [ ] always (not recommended) [ ] when reporting event data (slave devices only) [ ] when sending multi-fragment responses (slave devices only) [ ] sometimes. If 'sometimes', when? ______________________________________________ [x] configurable, proces...

  • Page 68

    Requires data link layer confirmation: pulse off [ ] never [ ] always [ ] sometimes [x] configurable latch on [ ] never [ ] always [ ] sometimes [x] configurable latch off [ ] never [ ] always [ ] sometimes [x] configurable queue [x] never [ ] always [ ] sometimes [ ] configurable clear queue [x] ne...

  • Page 69

    Supported description function code yes set the output directly respond with status of control point direct operate 5 yes set the output directly no respond direct operate - no ack 6 freeze function codes yes copy the specified objects to freeze buffer respond with status of operation immediate free...

  • Page 70

    Supported description function code no save the configuration respond with status of operation save configuration 19 no enable unsolicited messages respond with status of operation enable unsolicited messages 20 no disable unsolicited messages respond with status of operation disable unsolicited mes...

  • Page 71

    Qualifier code of response message function code of response message qualifier code of request message function code of request message description variation data object type 17,28 129,130 6,7,8 1 binary input change without time 1 2 17,28 129,130 6,7,8 1 binary input change with time 2 2 17,28 129,...

  • Page 72

    Qualifier code of response message function code of response message qualifier code of request message function code of request message description variation data object type 0,1 129,130 16-bit frozen counter 2 21 0,1 129,130 32-bit frozen counter without flag 9 21 0,1 129,130 16-bit frozen counter ...

  • Page 73

    Qualifier code of response message function code of response message qualifier code of request message function code of request message description variation data object type echo 129 17,28 3,4,5,6 16-bit analog output block 2 41 7 2 time and date 1 50 7 129,130 time and date cto 1 51 7 129,130 unsy...

  • Page 74

    74.

  • Page 75: Index

    Index a activation information properties ....................................................................................................... 31 adding data object ..................................................................................................... 18 gateway object ...............

  • Page 76

    D data object adding ........................................................................................................... 18 data object configuring ..................................................................................................... 29 delta (del) iec 61850 data modeling ......

  • Page 77

    Integer controlled step position information (isc) iec 61850 data modeling ................................................................................ 61 integer status (ins) iec 61850 data modeling ................................................................................ 60 properties ....

  • Page 78

    Logical node .................................................................................................. 26 logical node name plate .................................................................................. 41 measured value (mv) ..........................................................

  • Page 80

    — abb oy medium voltage products p.O. Box 699 fi-65101 vaasa, finland tel. +358 10 22 11 fax. +358 10 224 1094 abb inc. Medium voltage products 655 century point lake mary, fl 32746, usa tel: +1 407 732 2000 fax: +1 407 732 2335 www.Abb.Com/medium-voltage 1mrs756567 h/24.5.2017 © copyright 2017 abb....