Accu-Steam EG24A Installation & Operator's Manual - page 36
Accu-Steam™ G2 Electric Installation and Operators Manual
MP5018-1702
PAGE 33
PM TASK DESCRIPTION
Daily
Biannual Yearly
Verify that the appliance is level and properly located under the
hood.
X
X
Verify that the temperature controller is working properly and that
there are no rips in the overlay.
X
X
X
Check that the splash shield at the top of the control panel is un-
der the rail provided. If not water and or grease can migrate into
control panel.
X
X
Inspect the control compartment for foreign particulate and any
loose wiring or connections.
X
X
Check that the power supply cord is not frayed, outer covering is
not degraded or any bare cooper is visible. Replace if required.
X
X
X
Verify amp draw to listed amp requirements on the data tag of the
appliance.
X
X
If on an AccuTemp Stand verify mounting fasteners are in place
and tight. If the stand has casters check that the wheels are intact
and that they are mounted correctly. If grease covered clean with
a mild detergent and clean water. Dry completely . Apply a food
grade silicone to the locking mechanism.
X
X
X
Complete a 9 point temperature test to check for even
temperature across the surface of the cooking surface.
X
X
Check for grease buildup in the grease drawer container and
clean it with a damp towel saturated with a mild detergent and
clean water. Dry with a clean dry towel.
X
X
X
After all metallic areas are cool to the touch Clean external metal
surfaces except the cooking surface. with a damp clean towel
saturated with a mild detergent and clean water. Dry with a clean
dry towel.
X
X
X
Season the cooking surface as as outlined in this manual.
X