Antari DNG-200 User Manual - page 5
5-1. Function button
5-1-1. Setting of fog output interval:
Press the Function button once, the screen will display “Interval Set”. Under the time
counting mode of the timer , press Up/Down keys to adjust the interval of fog
output. The setting range is between 10 to 300 seconds.
5-1-2. Setting of fog output duration:
Press the Function button twice, the screen will display “Duration Set”. Under the time
counting mode of the timer, press Up/Down keys to adjust the duration of fog
output. The setting range is between 10 to 100 seconds.
To release the setting of Interval and Duration, press Timer button one time after initiating Timer
button and entering into work mode.
5-1-3. Setting of fog output volume:
Press the Function button three times, the screen will display four settings of “Volume Out”,
press Up/Down keys to select the setting of fog output volume.
Four volume settings:
Nonstop Burst -- The machine will continue to output low fog, the volume is automatically
adjusted by the machine based on the working temperature.
High Volume -- About 60% output volume.
Medium Volume -- About 52% output volume.
Low Volume -- About 35% output volume.
5-1-4. Setting of DMX 512 address
Press the Function button four times, the screen will display “DMX 512 Add “, press
Up/Down keys to set the machine address the same as that of DMX console.
Please refer to DMX setting description for more DMX setting information.
5-2. Timer function key
Initiate timer function to enter Interval and Duration function mode, press Timer one more Timer
to release the function.
5-3. Volume function key
Used for setting Volume Out (Fog volume output), a total of four setting values. After initiating the
machine will request for the fog volume according to the setting output mode, press Volume key
one more time to release the function.
5-4. Manual function key
Press down Manual key the screen will display “Manual Output”, under this function the low fog
has the biggest fog output volume.
1.
Sub-menus:
-->Interval Set
-->Duration Set
-->Volume Out
-->Nonstop Burst
-->High Volume
-->Medium Volume
-->Low Volume
-->DMX 512 Add
2.
Up-/Down-button
3. Timer-button
4. Volume-button
5. Manual-button
DNG-200