Antari W-515 User Manual - page 7
3.
The included transmitter has been registered before shipment. User
can use it directly without any setting. The initial setting is pressing
button A can trigger the machine and pressing button B can stop it.
4.
If user wants to use other transmitters (except the included one) to
control machine, the setting must be completed within 15 seconds
after switching on machine.15 seconds after switching on machine, it
will leave “transmitter setting mode” automatically.
If user wants to register other 3 transmitters, when machine is
turned on and LCD (Liquid Crystal Display) screen shows “Wireless
Setup”, user has to press the button A of each transmitter for 1
second rapidly within 15 seconds to complete the registration of the
3 transmitters.
Please note that 15 seconds after switch on machine, when LCD
screen shows “Wireless Setup OK”, it represents that machine has
left “transmitter setting mode”. At this point, user can not add any
transmitter to the receiver.
If user wants to use 1 transmitter to control 2 or more machines, user
has to turn on 2 (or more) machines at the same time, and press the
button A of the transmitter when the LCD screen shows “Wireless
Setup” for 1 second within 15 seconds. (The same procedure as
registering transmitter to 1 machine)
5.
If no any new transmitter is registered when machine is switched on,
the memory of the receiver will remain the same record of last
operation.
6.
Please note if a new transmitter is registered when machine is
switched on, no matter how many new transmitters is registered (at
most 5), all previous transmitters registered record will be cleared
(overridden).
This fog machines are DMX on board. It uses 1 channel to control volume
output. This channel has a value range of 0 to 255. Timer functions such as
duration and interval can be programmed using the DMX controller or the
DMX control software used by the lighting and effects operator.
Between the values 6 to 255 the volume of fog output is regulated. With 6
being the minimum volume of fog produced and 254 approaching the
maximum. The volume output rises as the DMX value is increased.
If the unit is assigned to DMX address 124 e.g., Channel A corresponds
to DMX address 124.
Setting Example 1:
Setting Example 2:
If Channel A has a value from 0 to 5, the unit is OFF.
Note:
On-board DMX settings