5.3 Pinouts for RS-232 Cable
The connections for the RS-232 connectors are as follows:
AVT-3190 Connector Pinout
PC Serial Connector Pinout
1, NC
1, NC
2, TxD
2, RxD
3, RxD
3, TxD
4, NC
4, NC
5, GND
5, GND
6, NC
6, NC
7, NC
7, NC
8, NC
8, NC
9, NC
9, NC
RS-232 Codes
RS-232 Code Implementation:
All Command and Response codes are six (6) bytes.
For every Command, the response is the same code.
Only PWR*** & VER*** codes are available when the unit is in the powered
down status (where *** are the last three bytes of the six byte code group).
Some commands result in a wait state wherein no additional commands will
be accepted until the unit issues a RDY*** response.
Data Protocol:
Baud Rate:
9600 bps
Data Bits:
8 Bits
Parity:
None
Stop Bits:
1 Bit
Note:
Some commands require more time to execute than others. Any user written RS -
232 control program should include processing of the echoed Response codes
before attempting to execute a new command to avoid data collisions.
RS-232 Codes
The following table contains the six byte code groups, the RDY*** codes (where
relevant) and a comment section that provides plain text descriptions of the
action that will be taken by the AVT-3190HD when given the codes.Make certain
that the data structure is as specified when using the RS-232 capability.