5.5 Detection Sensitivity Adjustment
Remark: Adjust each of detection sensitivity must be under the unit is stand-by
state.
Operation
Self-
checking
Feeding
Operation
Button
Function
Counting
Mode
Outer
Display
Detection
Sensitivity
Adjustment
5.5.1 Ultraviolet Sensitivity Adjustment
Press the button for once with showing " " in the batch display(refer to Fig.8)
" " means ultraviolet detection , " "means low level sensitivity. If you want to change
the sensitivity, please press button for again, the batch display shows " "
" " means high level .The unit will save the setting after 1.5 seconds and enter the
stand-by state.
UV
UV
Fig.8