Fit the Standard Flue Diverter supplied into the hole in the top of the oven for under ventilation hood
installation and secure with screws. For direct venting, FlueAdapter and Draft Hood must be placed into
the hole on top of the oven.
Four casters (two with wheel brakes) and the mounting hardware are packed and included in the
shipment if ordered. Install casters with wheel brakes on the front of the unit. Installation of the unit
should be madewithaconnector that complies with the latest edition of the Standard for Connectors for
Movable GasAppliances ANSI Z21.69 in the USA (CAN CSA-6.16 in Canada) and a quick-disconnect
device that complies with the latest edition of the standard for quick disconnect devices for use with gas
fuel ANSI Z21.41 in the USA (CSA 6.9 in Canada). Adequate means must be provided to limit the
movement of the appliance without depending on the connector and any quick disconnect device or its
associated piping to limit appliance movement.
The restraint should be attached to the rear legs of the oven on which casters are mounted. If
disconnect of the restraint is necessary, the restraint should be immediately reconnected after the
appliance has been returned to its originally installed position.
Move the oven to its final location keeping the minimum clearance from the back of the oven to the wall.
This clearance is necessary for safe operation and to provide proper air flow to the burner chamber.
C. INSTALLATIONWITHCASTERS (OPTIONAL): Refer to Figure 4
D. LOCATIONAND MINIMUM CLEARANCES:
MINIMUM CLEARANCES FROM COMBUSTIBLE AND NONCOMBUSTIBLE CONSTRUCTION
Under Ventilation Hood
Direct Venting
RIGHT WALL
1”
1”
LEFT WALL
1”
3”
REAR WALL
3”
3”
SUITABLE FOR INSTALLATION ON COMBUSTIBLE FLOOR WHEN
INSTALLEDWITHLEGSORCASTERSPROVIDED.
!
!
CAUTION: DO NOT SET THE OVEN WITH ITS BACK FLAT AGAINST THE
WALL. IT WILL NOT OPERATE PROPERLY UNLESS THERE IS AT LEAST
THREE INCHES BREATHING SPACE BEHIND THEOVEN
!
!
E. GAS CONNECTION:
The ovens should not be installed on the same gas supply line with space heaters, boilers or other gas
equipment with high intermittent demand.
The installation of the oven must conform to the latest local codes or
The appliance must be isolated from the gas supply piping system by closing its manual shut-off valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than ½
psig (3.45kpa). The appliance and its shut-off valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of ½ psig (3.45kpa).
Use a pipe joint compound that is resistant to the action of liquefied petroleum gases when making gas
connections. For Propane gas, use at least ½” (13 mm) pipe or tubing with a 5/8” (16 mm) inside
diameter. For Natural gas, use ¾” (19 mm) pipe.
National Fuel Gas Code, ANSI
Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code,
CAN/CGA-B149.2.