BaltGaz LUX User Manual - page 29
User’s and technical staff manual
21
9
POSSIBLE FAILURES AND METHODS OF THEIR ELIMINATION
Table 6. Possible failures of the appliance «BaltGaz NEVALUX-6011»
Error
code
Failure
Probable reason
Methods of elimination
Insufficient water consumption (less than 2,5 l/min) Increase water consumption.
No spark discharge
between the plug and
ignition burner before the
beginning of water flow
through the appliance
, the temperature indicator
is not glowing
температуры не
светится.
There is no power element or it is discharged.
Incorrect power element installation.
Install an operative power element
correctly
The contacts or the connection circuit are
disrupted.
Check the connections and if necessary
clean up the contacts.*
Water flow sensor is out of order.
Replace the water flow sensor.*
Water unit is out of order (the membrane is
destroyed).
Repair or replace the water unit.*
The electronic control block is out of order.
Replace the electronic control block.*
Appearance of soot deposit on the plug’s electrode. Effectuate cleaning of the plug’s electrode
from soot deposit.*
Е0
The appliance switches
off.
Gas supply stop.
Address to the responsible gas facilities
service.
Presence of air in the gas pipelines.
See p. 3.1.
The stop valve on the gas line by the inlet into the
appliance is closed or insufficiently opened.
аппаратом.
Open the stop valve on the gas pipeline
completely.
Absence or low pressure of gas in the duct.
Address to the responsible gas facilities
service.
The LPG reserve in the cylinder has expired
Replace the LPG cylinder .
The connection of the electronic control block to
the flame sensor, the electromagnetic valve of the
ignition burner is disrupted.
Check the connections, if necessary, clean
up the contacts or replace the cables.*
Е1
In 60 s after the spark
discharges begin the
electronic control block
does not detect the signal
from the flame sensor
The flame sensor is out of the zone of the ignition
burner’s flame or its electrode touches the details
of the ignition or main burner.
Adjust the flame sensor’s position (its
electrode must be in the zone of the
ignition and main burners’ flame and must
not touch the burners’ details).*
Contamination of the nozzle or air inlet duct of the
ignition burner.
Clean the ignition burner.*
The electromagnetic valve of the ignition burner is
out of order.
Replace the valve (or the valve block).*
The gap between the ignition plug and the nozzle
of the ignition burner is disrupted.
Install a gap of 4…5 mm between the
plug’s electrode and the ignition burner’s
nozzle.*
The high-voltage cable is put onto the ignition plug
not up to the stop (the spark goes to the burner’s
manifold).
Put the high-voltage cable onto the
ignition plug up to the stop.*
Appearance of soot deposit on the plug’s electrode
or on the flame sensor’s electrode
Effectuate the cleaning of the plug’s or the
flame sensor’s electrode from soot
deposit.*
Actuation of
electromagnetic valves
occurs before the
appearance of signal from
the water flow sensor.
The electromagnetic valves are out of order.
Replace the electromagnetic valve (or
valve block) that is out of order).*
Е3
The electronic control block is out of order .
Replace the electronic control block.*
The flame sensor transmits
a signal about flame
presence before the
appearance of signal from
the water flow sensor
пламени до появления
сигнала от датчика
протока воды.
An attempt to ignite the appliance from an
extraneous flame source.
Effectuate the appliance’s ignition in
accordance with section 3.
Е4
The electronic control block is out of order.
Replace the electronic control block.*
Е5
The electronic control
block does not receive a
signal from the hot water
temperature sensor.
The connection between the electronic control
block and the water temperature sensor is
disrupted.
Check the connection, replace the water
temperature sensor if necessary .*
Failed seven-times attempt
to ignition (the ignition
burner ignites, than the
main burner ignites and
then in some seconds the
main burner’s flame goes
out and the ignition
process repeats)
запальная, затем
Open the gas stop valve by the inlet into
the appliance completely.
Low gas pressure
Address to the responsible gas facilities
service.( or replace the LPG cylinder ).
Е7
Clean the gas filters.*
The flame sensor is not in the zone of the main
burner’s flame.
Adjust the flame sensor’s position (its
electrode must be in the zone of the
ignition and main burner flames).*
The electromagnetic valves are out of order
Clean or replace the electromagnetic
valves.*