BaltGaz LUX User Manual - page 7
9
* Reference parameters for p. 2.2.13, 2.2.14 - at water pressure
at least 250 kPа by the inlet into the operating
appliance;, for. 2.2.26 - when using alkaline power elements with high energy output ratio.
Main particularities of the appliance:
-
The appliance is automatically switched on when the hot water tap is opened (at water consumption
more than 2,5 l/min);
-
The ignition burner automatically switches off after the main burner ignites;
-
The appliance keeps (within the bounds of its heating effect) the set hot water temperature when water
consumption, inlet water temperature and gas pressure is changed:
-
On the digital display there is shown the temperature of water running out of the appliance and the
temperature set by pressing the control buttons;
Technical characteristics
NEVALUX-6014
2.2.1. Rated heating power, kW
21
2.2.2. Rated heating effect, kW
18
2.2.3. Rated heating power of the ignition burner, kW, not more than,
0,17
2.2.4. Gas type
NG/LPG
2.2.5. Family; gas group
2
nd
; Н / 3
rd
; B/P
2.2.6. Rated gas pressure, kPа (mm w.g.):
NG (G20, 2
nd
family, group H)
LPG (G30, 3family, group B/P)
1,3 (130)
2,0 (200)
2,9 (300)
2.2.7. Rated gas consumption , m
3
/h
NG (G20, 2
nd
family, group H)
LPG (G30, 3family, group B/P)
2,2
0,8
2.2.8. Performance index, %, not less than
84
2.2.9. Supplied water pressure for the appliance’s normal operation, kPa
30...600
2.2.10. Maximal water pressure (at water’s heat expansion the pressure must not exceed
this value), kPa
1000
2.2.11. Minimal water flow (for ignition), l/min
2,5
2.2.12. Minimal water pressure (for ignition), not more than, kPa
15
2.2.13. Water consumption at heating for Δ=40 °С, l/min
7
2.2.14. Water consumption at heating for Δ Т=25 °С, l/min
11,0*
2.2.15. Required rarefaction in the exhaust flue, Pа (mm w.g.),
Not less than
Not more than
1,96 (0,2)
29,4 (3,0)
2.2.16. Mass consumption of combustion products NG/ LPG at rated heating power,
g/s
7,4/8,0
2.2.17. Average temperature of combustion products,
С
150
2.2.18. Minimal allowable inlet gas pressure at the appliance’s operation, Pa (mm w.g.)
784 (80)
2.2.19. Combustion products temperature, °С, not more than
110
2.2.20. Appliance’s ignition type
electronic
2.2.21. Appliance’s overall dimensions, mm:
Height
Width
Depth
565
290
221
2.2.22. Weight of appliance, NET /GROSS, kg, not more than
10,5/11,5
2.2.23. Diameter of the nozzles of the main burner, mm :
NG 1,3 kPа (G20, 2
nd
family, group Н)
2,0 kPa
LPG 2,9 kPа (G30, 3
rd
family, group В/Р)
1,28
1,14
0,79
2.2.24. Diameter of the nozzles of the ignition burner, mm :
NG (G20, 2
nd
family, group H)
LPG (G30, 3
rd
family, group B/P)
0,55
0,35
2.2.25. Type and voltage of power element, V
LR20; 1,5 В
2.2.26. Continuous operation with one power element, h
250*