BaltGaz LUX User Manual - page 30
User’s and technical staff manual
22
Error
code
Failure
Probable reason
Methods of elimination
Jamming of the water or gas unit stem (water flow
sensor is constantly closed).
Repair or replace the unit that is out of
order.*
Appearance of soot deposit on the flame sensor’s
electrode.
Effectuate the flame sensor’s electrode’s
cleaning from soot deposit.*
Е8
Switching the appliance
off by the draught sensor
The error code appears on
display in 2-5 minutes
after the appliance was
switched off if the water
tap is not closed.
No draught in the flue pipe.
Clean the flue pipe.*
Draught sensor failure or disruption of its
connection.
Check the joints and clean up the
contacts or replace the details that are out
of order if necessary.*
99
The number 99 is
flickering for some time,
then the code LO is
shown on display and the
appliance switches off.
After this repeats seven
times the error code Е7
appears.
Short circuit in the circuit of the water
temperature sensor or inside of the connector’s
terminal strip.
Remove the short circuit or replace the
sensor together with the connection
cables.*
LO
Insufficient gas
consumption for the main
burner’s normal
operation.
Small water consumption (less than3,5 l/min).
Increase water flow through the appliance.
Clean the heat exchanger’s pipes and the
hot water pipe* from scale deposit or
address to the community facilities in
order to eliminate the cause of low water
flow in the water supply network.
Set hot water temperature is not much higher than
the cold water temperature by the inlet into the
appliance.
Set a higher hot water temperature.
Н1
The appliance doesn’t
heat water to the set
temperature
High hot water temperature is set at big water
consumption.
Set a lower temperature of hot water or
reduce water flow through the appliance
(see p.3.2).
Low gas pressure.
Open the gas stop valve by the inlet into
the appliance completely.
Address to the responsible gas facilities
service ((or replace the LPG cylinder ).
Clean the gas filters.*
Dust deposit in the main burner’s channels (the
main burner’s flame is weak, stretched out, with с
yellow smoky tongues).
Clean the main burner.*
Soot deposit on the heat exchanger’s fins or scale
deposit in the heat exchanger’s pipes.
Clean the heat exchanger from soot and
its pipes and the hot water pipe from
scale deposit.*
Water and gas unit or the electronic control block
is out of order
Repair or replace the water and gas unit
or the electronic control block
-
The main burner ignites
with a “clap” and the
flame casts out of the
casing’s viewing window.
The ignition burner’s flame is small or bends
aside and does not reach the main burner (the
nozzle is contaminated or the air inlet duct to the
ignition burner is contaminated with dust, low gas
pressure).
Clean and install the ignition burner
correctly.*
-
Small water consumption
by the appliance’s outlet
at normal water flow in
the pipeline.
Scale deposit in the heat exchanger’s pipes or in
the hot water outlet pipe.
Clean the heat exchanger’s pipes and the
hot water pipe from scale deposit.*
Water filters are contaminated.
Effectuate water filters cleaning.*
-
Unstable operation of the
appliance: sustainable hot
water temperature
fluctuations are detectedн
Small water consumption is set.
Increase water consumption.
Water pressure in the water supply network is less
than 30 kPa (water consumption is less than 3,5
l/min).
Address to the community facilities in
order to eliminate the cause of low water
flow.
The appliance’s connection to the water supply
network was effectuated violating the
requirements of this manual.
Effectuate the appliance’s connection to
the water supply network in accordance
with the requirements of p.7.3.3 *
-
The main burner’s flame
doesn’t go out when the
hot water tap is closed.
Water or gas unit stem jamming.
Close the gas stop valve by the inlet into
the appliance and call a specialized
service organization.