    Quick start guide self-contained smart camera with user-friendly vision manager software this guide is designed to help you set up and install the ve series smart camera. For complete information on programming, performance, troubleshooting, dimensions, and accessories, please refer to the instructi...

  • Page 2

    Display figure 2. Display with home screen the display is a 2-line, 8-character lcd. The main screen is the home screen, which shows the name of the current inspection and the slot number (inspection location). Use the display to view or change several sensor settings. Indicators four led indicators...

  • Page 3

    8. If you are using a filter: thread the filter (4) onto the front of the c-mount lens. 9. If you are using a linear polarization filter: rotate the outer portion of the filter mount to determine the position where glare is reduced the most, and use the locking thumbscrew to fasten the filter in pos...

  • Page 4

    Wiring diagrams ve load + - 12-30v dc output power supply output common ve output figure 5. Pnp output ve + - 12-30v dc output common ve output load output power supply figure 6. Npn output ve input common + - ve input opto-isolator 12-30v dc pnp driver input power supply figure 7. Pnp input ve inpu...

  • Page 5

    1. Confirm the network connections. A) click the start button, then on the start menu, click control panel. B) in control panel, click network and internet, then click network and sharing center, and then click change adapter settings. C) right-click on the connection that you want to change, then c...

  • Page 6

    Sensor screen the sensor screen displays the information needed to create or modify an inspection. 1. Screens—home, sensor, inspection logs, inspection management, system settings 2. Manual trigger button—click to manually trigger the sensor 3. Inspection list—select the desired inspection to start,...

  • Page 7

    7. After checking and adjusting the lighting, run auto exposure a second time or adjust the exposure manually by expanding the exposure parameters and moving the slider or entering a specific exposure time. 8. Adjust the focus. A) place the part so that the area to be focused appears in the center o...

  • Page 8

    1. On the inspection management screen, click transfer. 2. Change the destination folder, if desired. A) click above the right column. An explorer window opens. B) navigate to the desired location, network location, or storage device. C) click select folder. The folder is selected and the window clo...

  • Page 9

    Enter button press enter to: • access the sensor menu • access the submenus • save changes in the sensor menu, a check mark in the lower right corner of the display indicates that pressing enter accesses a submenu. Escape button press escape to: • leave the current menu and return to the parent menu...

  • Page 10: Top Menu

    Sensor menu enter shortcuts menu no yes yes 100 hd 100 fd focus# home screen ether pchange io ve series user interface enter top menu top menu image info sub menus or or go back to parent menu select menu item press to save setting press and hold to go back to home screen speed link subnet gateway s...

  • Page 11

    Specifications power 12 v dc to 30 v dc (24 v dc ± 10% if a banner light source is powered by the sensor) current: 400 ma maximum (exclusive of load and lights) use only with a suitable class 2 power supply, or current limiting power supply rated 12 v to 30 v dc, 1 a supply protection circuitry prot...