Banner VE200G1A Quick Start Manual - page 8
1.
On the
Inspection Management screen, click Transfer.
2. Change the destination folder, if desired.
a)
Click
above the right column.
An explorer window opens.
b) Navigate to the desired location, network location, or storage device.
c) Click Select Folder.
The folder is selected and the window closes.
The path to the location displays above the right column.
3. Select the desired inspection from the inspection list in the left column.
4.
Click
.
Inspection name.idb displays in the right column and the inspection is transferred (saved) to the selected location.
Configure the Discrete I/O
From the
System Settings screen, select Discrete I/O to change the discrete I/O settings.
Figure 10. Discrete I/O
For more details, see the Instruction Manual.
Sensor Display
The LCD display on the top of the sensor provides access to view or change several settings without using Vision Manager. The display
provides limited programming options:
• ETHER—Ethernet settings
• PCHANGE—Product change
• IO—Input/Output settings
• IMAGE—Image settings
• INFO—Sensor information
• SYSERROR—System errors, if present
• DISPLAY—Display settings
• REBOOT—Reboot
Access the sensor menu by pressing Enter
from the Home Screen.
See the Instruction Manual, p/n 191666, for more information.
Sensor Display Interface
Down and Up Buttons
Press Down and Up to:
• Navigate the menu systems
• Change programming settings
When navigating the menu systems, the menu items loop.
VE Series Smart Camera
8
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 191667 Rev. C