BarAid 500 Installation And Operation Instructions Manual - 8 Faults
1617-A-01-09
11
dE
GB
F
nl
Press and hold (3 seconds) the program button
➁
until the actual
temperatures (°c) are displayed (top = rinse, bottom = wash).
The indicators go out 10 seconds after releasing the program button.
Permanent temperature display can be activated on request by the
service technician.
–
codE
possIBlE causE
mEasuREs
al
Drain hose blocked.
Restart drain cycle. Clean drain hose if necessary.
hEI
Rinse booster heating defective.
Call the after sales service.
d 0
OPTION
External demineralisation cartridge depleted.
Replace cartridge.
sal
Salt deficiency
(only with built-in softener).
Refill the softener with granular regeneration salt.
The service indicator
➆
is illuminated and:
codE
possIBlE causE
mEasuREs
FIl
Shut-off valve is closed.
Open shut-off valve at site and switch on machine again.
Fill valve or fill system defective.
Call the after sales service.
sIE
Tank strainer not correctly positioned.
Put strainer correctly in place.
ul
Drain hose blocked.
Clean drain hose and restart drain cycle.
Fill system or drain system defective.
Call the after sales service.
F01
Temperature probe "rinse booster" defective.
Call the after sales service.
F02
Temperature probe "tank" defective.
Call the after sales service.
F03
Pressure transmitter "rinse booster" defective.
Call the after sales service.
F04
Pressure transmitter "tank" defective.
Call the after sales service.
othER IndIcatIons
Moving light point in the upper display:
codE
causE
mEasuREs
. .
.
Softener regeneration active (only with built-in
softener).
None.
7 pREVIEw oF tEmpERatuREs
8 Faults
according to the fault, an error code will be shown in the upper
display
➄
(see table below).
please report the error code to the service technician.