BarAid 500 Installation And Operation Instructions Manual - 4 Start-Up
1617-A-01-09
7
dE
GB
F
nl
4.1 dEtERGEnt
do not use any acidic detergent products with the built-in detergent
pump! (the ph-value has to be higher than 7.)
Place the suction hose into the detergent container.
Fill the suction hose according to chapter 4.3.
4.2 RInsE aId
Place the suction hose (blue marking) into the rinse aid container.
Fill the suction hose according to chapter 4.3.
the dosing pumps can operate to a maximum head height
of 1.5 m. do not confuse the containers !
Use only commercial detergent and rinse aid. p
lease pay attention to
the manufacturers safety instructions.
Before changing to a different product type (even from the same sup-
plier), the suction hoses must be rinsed thoroughly with fresh water
(procedure as described under 4.).
Otherwise, the mixing of different types of chemicals will cause
crystallisation, which may result in a malfunction of the dosing pump.
4.3 pRImInG thE suctIon hosEs
attEntIon:
the machine has to be switched off.
open the door.
Push stop button
➂
and program button
➁
simultaneously until the
upper display
➄
shows "ch1".
Push program button repeatedly, until "d" is displayed.
close the door.
In the upper display appears "sF1", in the lower one "0".
4.3.1 dEtERGEnt suctIon hosE
Pushing the on
/oFF button
➀
activates the hose priming for
60 seconds.
Each cycle can be interrupted by pushing the on/oFF button again.
4.3.2 RInsE aId suctIon hosE
Push the p
rogram button
➁
.
In the upper display
➄
appears "sF2", in the lower one
➃
"0".
Pushing the on/oFF button
➀
activates the hose priming for
60 seconds.
Each cycle can be interrupted by pushing the on/oFF button again.
4.3.3 tERmInatIon oF hosE pRImInG
open door and close it again or do not press any button for