BarAid 500 Installation And Operation Instructions Manual - page 12
1
1617-A-01-09
dE
GB
F
nl
attEntIon:
the machine has to be switched off.
open the door.
If the door will be closed or if no button is pressed for 10 seconds,
the indicator automatically switches off and the new settings will
be saved.
Therefore the setting procedure can be interrupted at any time.
9.1 adjustmEnt oF dEtERGEnt dosaGE quantIty
Push stop button
➂
und program button
➁
simultaneously until in
the upper display
➄
"ch1" appears.
In the lower display
➃
appears e.g.:
"8.0" = pre-adjusted value of the detergent dosage time =
8.0 s ≈ 2.4 g/l.
To adjust the detergent dosage time, push on
/oFF button
➀
repeatedly, until the desired value (0-50 s ≈ 0-15.4 g/l) appears.
Adjustment should be done in accordance with chemical suppliers
recommendations.
9.2 adjustmEnt oF RInsE aId dosaGE quantIty
Push program button
➁
again.
In the upper display
➄
appears "ch2".
In the lower d
isplay
➃
appears e.g.:
"9.0" = pre-adjusted value of the rinse aid dosage time =
9.0 s ≈ 0.3 g/l.
To adjust the rinse aid dosage time, push on/oFF button
➀
repeatedly, until the desired value (0-50 s ≈ 0-1.6 g/l) appears.
Adjustment should be done in accordance with chemical suppliers
recommendations.
9.3 adjustmEnt oF watER haRdnEss
with optional softener only.
To adjust the softener to the local water hardness (obtain details from
local water authority:
Push p
rogram button
➁
repeatedly until in the upper display
➄
"h02" appears.
Push on/oFF button
➀
repeatedly, until the required value (h01-h04)
will be displayed.
h01 = up to 9 °eh / h02 = 10 to 18 °eh / h03 = 19 to 26 °eh /
h04 = 27 to 38 °eh water hardness (°eh = Clark).
–
–
–
–
–
–
–
9 sEttInGs and countER ValuEs