Barco R9002240 Installation Manual - page 22
AC power connection
6-2
5975698 BARCOGRAPHICS 1609s 220198
AC Power check
Check the power voltage which is determined by the Art. No. on the
identification label pasted on the backside of the projector.
Projectors with the Art. No. R9002240 must be connected to a 230
VAC power source.
Projectors with the Art. No. R9002249 must be connected to a 120
VAC power source.
When the power voltage is different from that of the wall outlet,
proceed to AC Input power voltage adaptation of the projector.
AC Input power (mains) voltage adaptation
Attention !
The BARCOGRAPHICS 1209s - R9002240 leaves the factory to
operate on a mains (power) input of 230 Vac.
The BARCOGRAPHICS 1209s - R9002249 leaves the factory to
operate on a mains (power) input of 120 Vac.
Adaptation of the power input of the projector between 230 Vac and
120Vac or vice versa is possible.
Follow the procedure as described below to adapt the voltage :
1 WARNING: turn off the projector and be sure the AC Power Cord
is unplugged from the wall outlet before starting the procedure !
2 Open the top cover (see 'Access to controls' on p.4-1).
3 Unscrew the retaining screws of the power input protection plate.
4 Remove the power input protection by sliding it a little backwards
and lifting it up.
Retaining screws
5 Pull out the 'Power selector plug' and re-insert it as illustrated in
drawing, depending on the AC power of the wall outlet in the room.
6 Pull out the fuses and place the correct fuses in their sockets. See
the table below for the correct fuses.
7 Re-install the protection plate. Insert the plate until the pins fit into
the grooves of the bottom plate. The right side of the plate must
be pushed behind the metal frame. The notch fits around the bolt.
Secure the correct position by turning in the 3 screws.
230V
120V
230V operation
120V operation
2xT5A/250V
2xT10A/250V
5
6
2
8
7
5
6
,
1
,5
5(027(
5
(
0
2
7
(
,5
56287
56,1
ART.NR : RXXXXXXX
SER.NR ; RXXXXXXX