7.8 Security settings
These settings can be used to secure the access to the
Annuncicom IC on several levels. The status is shown next
to each password (set or not set). Access is free for levels
without a password (default setting).
Save Configuration
Enter up to 24 characters to secure the saving of the
device configuration (Clicking the "Apply" button). Without
a valid password the device configuration can not be saved!
Enter 25 characters to erase the current key.
Save configuration password usage
If the password is set the user has to type in the password
in the "Save Config Password field" before hitting the
"Apply" button.
Without a valid password a warning will be displayed and
the changes don't save.
View Configuration
Enter up to 24 characters to secure the viewing of the
device configuration (Clicking the "Config" button).
Without a valid password the device configuration can not
be viewed! Enter 25 characters to erase the current key.
View configuration password usage
When the password is set the user clicking on the "Config"
link has to type in the password into the password field of
the pop up window (the user name does not matter).
Only one user can log in at a time. Further connections will
be refused while one user is logged in.
To log out click on the "Logout" link next to the "HOME"
icon in the menu bar.
Please hit your browser’s Reload button if the "Logout" link
is not visible while logged in.
Control / Command
Enter up to 24 characters to secure the access to all
control and command interfaces (WEB/CGI, Serial, TCP,
and UDP). Without a valid password the device can not be
controlled.
Enter 25 characters to erase the current key.
Note
This security option should be used very carefully and is
intended for advanced users only and helps to completely
secure the devices homepage against unauthorized access.
Level 4 to 6 (User)
Enter up to 24 characters to secure the access to
customized web pages in 3 levels. Intended for advanced
users only, for details see the Technical Documentation.
Without a valid password these user web pages cannot be
viewed. Enter 25 characters to erase the current key.
Listening
Choose which level is used for preventing unauthorized
listening to an Annuncicom IC as an Internet Radio, or "not
protected" for access for all.
SNMP Community RWrite
Choose a password for the Read and Write Community,
or "not protected" to ignore both the read and write
communities or "no write access"
SNMP Community Read
Choose a password for the Read Community, or "not
protected" to ignore the read community or "no access"
Note that the Community RWrite setting takes priority.
This means that if the Community RWrite is set to not
protected, Community Read is ignored.